Fail Timer Expired, State Complete
ExtremeWare Error Message Decoder 67
Fail Timer Expired, State Complete
<CRIT:EAPS> eaps_runtime.c 2429: Fail timer expired, while state is Complete,
EAPS="E05B"
Software Version
ExtremeWare 6.2.2 and later
Hardware Version
All
Explanation
This message indicates that the fail timer expired while the state is Complete. If there is an actual break
in the ring, the Master should receive a Link-Down message from the Transit. If the Master does not
receive a Link-Down message from Transit, and does not receive its own Health-Check-Pdu for 3
seconds, there is a problem in the ring that must be resolved as soon as possible.
Action
Troubleshooting is required immediately. Is there an actual break in the ring? Was a Link-Down_pdu
sent to the Master? Is the ring complete, but due to a misconfiguration of the Control VLAN, the Master
is not receiving its own PDUs? Is there a broadcast storm on the ring which is why the Master's PDUs
are getting dropped? Is there a hardware problem on one of the switches that is not allowing the
control PDUs to go through?