Specifications

532 ExtremeWare Error Message Decoder
Error Messages
EAPS Shared-port: Stopping the Domain Failed
EAPS Shared-port 1:1 - After setting mode, problem in stopping the domain
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” series
Explanation
This message indicates that the EAPS domains were not removed or unbound from the ESD domain.
ESD (EAPS Shared Port domain) mode can be configured as Partner or Controller.
While configuring the partner, if the ESD is running, the ESD domain is stopped before changing the
mode of the ESD.
Action
Confirm that there is no link between ESD and EAPS when the ESD is stopped.
Confirm that the EAPS domains are attached to ESD automatically when EAPS domains are enabled.
Changing the mode will disable the ESD and restart the EAPS domain when the mode change is
complete. If the problem appears again reconfigure the EAPS and ESD domains.