Specifications
156 ExtremeWare Error Message Decoder
Critical Messages
HTTPD Bind Failed
ERROR: httpd bind failed
Software Version
ExtremeWare 7.3
Hardware Version
All “i“ series and “e“ series
Explanation
This error message is logged during the web server TCP initialization. The message indicates that the
binding of the HTTP port to the newly created socket has failed. HTTP port could be the default port 80
or the configured alternate port.
The web server could be initialized during the switch startup or while configuring an alternate port
using the CLI command
enable web access-profile.
Action
If the error occurs during the switch startup, restart the switch.
If the error occurs while configuring alternate port, try configuring the port with a different port
number. If you see the message again, restart the switch.