Specifications

136 ExtremeWare Error Message Decoder
Critical Messages
Message Send Failed for Rx Queue on Port
sysObjSetLsm: Message Send (CLR_RST - 2) failed for Rx Queue, Port %P
Software Version
ExtremeWare 7.3 and later
Hardware Version
All
Explanation
The message posting to the link status monitoring (LSM) Rx Queue failed while enabling the LSM auto
restart feature for the port.
The auto restart feature for the port will remain disabled.
Action
Reboot the switch.