Specifications
Received PDUs from Two Nodes
ExtremeWare Error Message Decoder 103
Received PDUs from Two Nodes
<CRIT:EAPS> eaps_runtime.c 1424: Error!! Received "Health-Pdu" from another master
[MAC=<mac address>]
Software Version
ExtremeWare 6.2.2 and later
Hardware Version
All
Explanation
This message indicates that the EAPS domain configured to be the Master node has received an EAPS
PDU from another Master node on the same EAPS domain. This is not allowed.
Action
You must immediately configure one of the two Master nodes to be a Transit. A single EAPS domain
can have only one Master node.