6-4 EXTREMEWARE ENTERPRISE MANAGER INSTALLATION AND USER GUIDE
USING EXTREMEVIEW
• The name, type of switch, IP address, the ExtremeWare software version, and the last
reboot time are retrieved from the switch by the ExtremeWare Enterprise Manager.
Select a switch in the Component Tree on the left to display detailed configuration and
status information, as shown in Figure 6-3. This display shows additional information
that the Enterprise Manager has gathered from the switch agent.
Figure 6-3: The ExtremeView applet, switch status
Table 6-1: ExtremeView Switch Status Indicators
Status Light /Switch Status
Green Switch is up and OK
Yellow Switch is responding, but reports an error condition such as a fan or
power supply failure, or excessive temperature
Red Switch is not responding to Enterprise Manager status queries. This
may mean that the switch is down, that it is unreachable on the
network, or that the SNMP community strings have changed and the
ExtremeWare Enterprise Manager can no longer contact the switch.