Specifications

238 ExtremeWare XOS 10.1 Concepts Guide
Troubleshooting
The switch keeps aging out endstation entries in the switch Forwarding Database (FDB):
Reduce the number of topology changes by disabling STP on those systems that do not use redundant
paths.
Specify that the endstation entries are static or permanent.
Debug Mode
The Event Management System (EMS) provides a standardized way to filter and store messages
generated by the switch. With EMS, you must enable debug mode to display debug information. To
enable or disable debug mode for EMS, use the following commands:
enable log debug-mode
disable log debug-mode
Once debug mode is enabled, you can configure EMS to capture specific debug information from the
switch. Details of EMS can be found in Chapter 8, Status Monitoring and Statistics on page 91.
System Health Check
The system health check tests the backplane, the CPU, and I/O modules by periodically forwarding
packets and checking for the validity of these packets. If you observe a failure, please contact Extreme
Technical Support.
To enable system health check, use the following command:
enable sys-health-check slot <slot>
System health check is enabled by default.
To disable the system health checker, use the following command:
disable sys-health-check slot <slot>
System Odometer
Each field replaceable component contains a system odometer counter in EEPROM. You can use the
show odometer command to see how long an individual component has been in service since it was
manufactured. The odometer is supported on the following BlackDiamond 10808 components:
Master MSM and slave MSM
Backplane
All modules
The output from the show odometer command is similar to the following:
* BD-PC.1 # show odometer
Service First Recorded
Field Replaceable Units seconds Start Date
------------------------- ------- --------------