Release Notes
Table Of Contents
- Extreme Management CenterĀ® Release Notes Version 8.5.1
- Table of Contents
- Extreme Management Center Version 8.5 Release Notes
- 1. Enhancements in Version 8.5.1
- 2. Deprecated Features
- 3. Known Issues and Vulnerabilities Addressed
- 4. Installation, Upgrade, and Configuration Changes
- 4.1 Installation Information
- 4.2 Important Upgrade Considerations
- 4.3 ExtremeAnalytics Upgrade Information
- 4.4 ExtremeControl Upgrade Information
- 4.5 Fabric Configuration Information
- 4.6 Device Configuration Information
- 4.7 Firmware Upgrade Configuration Information
- 4.8 Wireless Manager Upgrade Information
- 5. System Requirements
- 5.1 Extreme Management Center Server and Client OS Requirements
- 5.2 Extreme Management Center Server and Client Hardware Requirements
- 5.3 Virtual Engine Requirements
- 5.4 ExtremeControl Agent OS Requirements
- 5.5 ExtremeControl Supported End-System Browsers
- 5.6 ExtremeControl Engine Version Requirements
- 5.7 ExtremeControl VPN Integration Requirements
- 5.8 ExtremeControl SMS Gateway Requirements
- 5.9 ExtremeControl SMS Text Messaging Requirements
- 5.10 ExtremeAnalytics Requirements
- 5.11 Ekahau Maps Requirements
- 5.12 Guest and IoT Manager Requirements
- 6. Getting Help
4. Installation, Upgrade, and Configuration Changes
35 of 51
When you delete an ExtremeXOS device that is configured as a flow source via the Flow
Sources table of the Analytics > Configuration > Engines > Configuration tab from the
Devices list on the Network > Devices tab, an error message is generated in the
server.log. The message does not warn you that the device is in use as a flow
source. Adding the device back in the Devices list on the Network > Devices tab or
removing the device from the Flow Source table fixes the issue.
The Flow Sources table on the Analytics > Configuration >
engine
> Configuration tab
may take a few minutes to load.
4.4 ExtremeControl Upgrade Information
4.4.1 General Upgrade Information
Before upgrading to Extreme Management Center 8.5, upgrade your ExtremeControl
engine version to 8.2 or 8.3. Additionally, both Extreme Management Center and the
ExtremeControl engine must be at version 8.5 in order to take advantage of the new
ExtremeControl 8.5 features.
NOTE: ExtremeControl 8.5 functionality is not supported on the 2S Series and 7S Series
ExtremeWireless Controllers.
You can download the latest ExtremeControl engine version at the Extreme Portal:
https://extremeportal.force.com. Be sure to read the
Upgrading to ExtremeControl 8.5
document (available on the Documentation tab of the Portal) for important information.
In addition, if your ExtremeControl solution utilizes a Nessus assessment server,
upgrade your assessment agent adapter to version 8.5 if you upgrade to the
ExtremeControl engine 8.5. Version 8.5 of the assessment agent adapter requires an
operating system with a 64-bit architecture.
4.4.2 ExtremeControl Version 8.0 and later
Beginning in version 8.0, ExtremeControl may fail to join Active Directory when
accessing as a Standard Domain User with Descendant Computer Objects ("Reset
password" permissions only) group member.
To allow this functionality, add the following permissions:
l Reset Password
l Validated write to DNS host name
l Validated write to service principal