Release Notes
Table Of Contents
- Extreme Management Center® Release Notes Version 8.4.4
- Table of Contents
- Extreme Management Center Version 8.4 Release Notes
- 1. Enhancements in Version 8.4
- 2. Deprecated Features
- 3. Known Issues and Vulnerabilities Addressed
- 4. Installation, Upgrade, and Configuration Changes
- 5. System Requirements
- 5.1 Extreme Management Center Server and Client OS Requirements
- 5.2 Extreme Management Center Server and Client Hardware Requirements
- 5.3 Virtual Engine Requirements
- 5.4 ExtremeControl Agent OS Requirements
- 5.5 ExtremeControl Supported End-System Browsers
- 5.6 ExtremeControl Engine Version Requirements
- 5.7 ExtremeControl VPN Integration Requirements
- 5.8 ExtremeControl SMS Gateway Requirements
- 5.9 ExtremeControl SMS Text Messaging Requirements
- 5.10 ExtremeAnalytics Requirements
- 5.11 Ekahau Maps Requirements
- 5.12 Guest and IoT Manager Requirements
- 6. Getting Help
4. Installation, Upgrade, and Configuration Changes
56 of 69
4.6 Device Configuration Information
4.6.1 VDX Device Configuration
To properly discover interfaces and links for VDX devices in Extreme
Management Center, enable three-tuple-if on the device.
NOTE: To enable three-tuple-if on the device in Extreme Management Center:
1. Access the Network > Devices tab.
2. Right-click on the device in the Devices table.
3. Select Tasks > Config > VDX Config Basic Support.
Additionally, for Extreme Management Center to display VCSfabric , the
NOSversion must be 7.2.0a or later.
Rediscover VDX devices after upgrading to Extreme Management Center
version 8.4.3.
4.6.2 VSP Device Configuration
Topology links from VSP devices to other VSP or ERS devices might not display
in a topology map (or might display inconsistently). To ensure topology map
links display correctly, verify that the VSP device is configured to publish its
management IP address in the autotopology (SONMP) data.
Ensure that the output of show sys setting command shows:
autotopology : on
ForceTopologyIpFlag : true
clipId-topology-ip : 0
If the output values displayed are different, configure the VSP device to publish
management IP address in SONMP data by executing the following CLI
commands:
(config)# autotopology
(config)# sys force-topology-ip-flag enable
(config)# default sys clipId-topology-ip