Release Notes
Table Of Contents
- Extreme Management Center® Release Notes Version 8.4.4
- Table of Contents
- Extreme Management Center Version 8.4 Release Notes
- 1. Enhancements in Version 8.4
- 2. Deprecated Features
- 3. Known Issues and Vulnerabilities Addressed
- 4. Installation, Upgrade, and Configuration Changes
- 5. System Requirements
- 5.1 Extreme Management Center Server and Client OS Requirements
- 5.2 Extreme Management Center Server and Client Hardware Requirements
- 5.3 Virtual Engine Requirements
- 5.4 ExtremeControl Agent OS Requirements
- 5.5 ExtremeControl Supported End-System Browsers
- 5.6 ExtremeControl Engine Version Requirements
- 5.7 ExtremeControl VPN Integration Requirements
- 5.8 ExtremeControl SMS Gateway Requirements
- 5.9 ExtremeControl SMS Text Messaging Requirements
- 5.10 ExtremeAnalytics Requirements
- 5.11 Ekahau Maps Requirements
- 5.12 Guest and IoT Manager Requirements
- 6. Getting Help
4. Installation, Upgrade, and Configuration Changes
55 of 69
4.5.5 Gateway Address Configuration Change
In versions of Extreme Management Center prior to 8.4.3, the Default Gateway IP
Address is configured as part of the VLAN. In 8.4, the Default Gateway IP
Address is configured as part of the VRF.
When enforcing VRFs to a device after upgrading to version 8.4, merge any
Default Gateway IP Addresses from the device into the configuration of Extreme
Management Center to prevent incorrect configuration of the device.
4.5.6 Upgrading VSP-8600
When upgrading from Extreme Management Center version 8.2 to version 8.3.
manually reload previously discovered VSP-8600 devices to gain access to
Fabric Connect features.
4.5.7 Removing Fabric Connect Configuration
Removing a device's Fabric Connect configuration by setting the Topology
Definition to <None> may fail if the device has Logical Interfaces assigned to
ISIS.
4.5.8 Password Configuration
Fabric Manager fails to onboard in Extreme Management Center if the root
password includes an ampersand (&) character. Additionally, if the
Administration > Inventory Manager > SCP tab contains a password that
includes an ampersand (&) in Extreme Management Center, the Fabric Manager
firmware does not download successfully.
Ensure you use a password without an ampersand (&) character.
4.5.9 VRFConfiguration
VSP SNMP performance is adversely affected as the number of VRF
configurations increases. This issue can be resolved by upgrading to VSP release
8.1.1 or later or VSP8600 series version 6.3.3 or later.