Release Notes

Table Of Contents
4. Installation, Upgrade, and Configuration Changes
52 of 69
4.3 ExtremeAnalytics Upgrade Information
Enabling or disabling the disk flow export feature might cause enforce
operations to time out. Enforcing again resolves the issue.
When you delete an ExtremeXOS device that is configured as a flow source via
the Flow Sources table of the Analytics > Configuration > Engines >
Configuration tab from the Devices list on the Network > Devices tab, an error
message is generated in the server.log. The message does not warn you that
the device is in use as a flow source. Adding the device back in the Devices list
on the Network > Devices tab or removing the device from the Flow Source table
fixes the issue.
The Flow Sources table on the Analytics > Configuration > engine >
Configuration tab may take a few minutes to load.
4.4 ExtremeControl Upgrade Information
4.4.1 General Upgrade Information
Before upgrading to Extreme Management Center 8.4.3, upgrade your
ExtremeControl engine version to 8.2 or 8.3. Additionally, both Extreme
Management Center and the ExtremeControl engine must be at version 8.4.3 in
order to take advantage of the new ExtremeControl 8.4.3 features.
NOTE: ExtremeControl 8.4 functionality is not supported on the 2S Series and 7S Series
ExtremeWireless Controllers.
You can download the latest ExtremeControl engine version at the Extreme
Portal: https://extremeportal.force.com. Be sure to read the Upgrading to
ExtremeControl 8.4 document (available on the Documentation tab of the
Portal) for important information.