Specifications
5
WWW.EXTREMENETWORKS.COM
Technical
Specifications
E1120 E2120 E2122 E3120
Length 30.5 cm (12 in) 76.84 cm (32.25 in) 79.38 (31.25 in) 79.38 (31.25 in)
Width 43.1 cm (16.9 in) 43.82 cm (17.25 in) 43.85(17.25 in) 43.85(17.25 in)
Height 4.4 cm (1.7 in) 4.45 cm (1.75 in) – 1U 4.38 (1.7 in) 4.38 (1.7 in)
Weight 4.3 kg (9.5 lbs) 21.6 kg (47.75 lbs.) 13.26 Kg 13.26 Kg
Operating Temperature
0° C to 40° C
(32° F to 104° F)
10° C to 35° C
(50° F to 95° F)
10 ° C to 35° C
(50 ° F to 95° F)
10 ° C to 35° C
(50 ° F to 95° F)
Storage Temperature
-20° C to 70° C
(-4° F to 158° F)
-40° C to 70° C
(-40° F to 158° F)
-40 ° C to 70 ° C
(-40 ° F to 158° F)
-40 ° C to 70 ° C
(-40 ° F to 158° F)
Humidity 5% to 90%, non-condensing 5% to 90%, non-condensing 5% to 90%, non-condensing 5% to 90%, non-condensing
19” Rack Mountable
1U configuration to fit standard
19” rack
(mounting kit included)
1U configuration to fit standard
19” rack
(mounting kit included)
1U configuration to fit standard
19" rack
(mounting kit included)
1U configuration to fit standard
19" rack
(mounting kit included)
Front and Rear Mount
I/O cabling at back of unit; power
cabling and power switch at the
rear
I/O cabling and power cabling at
back of unit; power switch at the
front
I/O cabling and power cabling
atback of unit; power switchat
the front
I/O cabling and power cabling
at back of unit; power switchat
the front
Data Ports 4 x 10/100/1000 Base-T
2 x SFP+ (GBICs sold separately)
2 x 10/100/1000 Base-T
2 x 1/10 Gbps SFP+ (GBICS Sold
Separately)
2x 1/10 Gbps BASE-T
2 x 10/25/40 Gbps QSFP28
(GBICS Sold Separately)
2x 1/10 Gbps BASE-T
Management Ports
1 x 10/100/1000 Base-T
1 x USB Port
Console Port DB9
1 x 10/100/1000 Base-T
5x USB Ports available. Use one.
Console Port RJ4
1 x 10/100/1000 Mbps Base-T
5 x USB 3.0 ports. Use one.
RJ45 Console Port
1 x 10/100/1000 Mbps Base-T
5 x USB 3.0 ports. Use one.
RJ45 Console Port
Power Specifications
Power (max): 150W
Voltage: 100-240 VAC
Frequency: 50-60 Hz
Power (max): 750 W (Redundant
Power Supply Sold Separately)
Voltage: 110/240 VAC
Frequency: 47-63 Hz
Power (max) : 1100 W
(Redundant Power Supply Sold
Separately)
Voltage: 110/240 VAC
Power (max) : 1100 W
(Redundant Power Supply Sold
Separately)
Voltage: 110/240 VAC
Frequency: 47-63 Hz
Regulatory/Safety
• UL 60950-1, 2nd EditionCSA
C22.2 No. 60950-1-07,2nd
Edition
• CB scheme: IEC 60950-1 AS/
NZS 60590-1 (Australia/New
Zealand)
• Mexico via NRTL
• BSMI CNS 14336-1 99 (Taiwan)
• CCC GB4943.1-2011, GB9254-
2008
• GB 176251-2012 (China)
• UL60950 - CSA 60950 (USA/
Canada)EN60950 (Europe)
• IEC60950 (International)
• CB Certificate and Report,
IEC60950 GS Certification
(Germany)
• GOST R 50377-92 -
Certification (Russia)
• Ukraine Certification (Ukraine)
• CE - Low Voltage Directive-
2011/65/EU (Europe)
• IRAM Certification (Argentina)
• UL60 950 - CSA 60 950
(USA/Canada)
• EN60 950 (Europe)
• IEC60 950 (International)
• CB Certificate and Report
• IEC60 950 GS
Certification(Germany)
• GOST R 50 377-92 -
Certification (Russia)
• Ukraine Certification (Ukraine)
• CE - Low Voltage Directive
• 20 11/65/EU (Europe)
• UL60 950 - CSA 60 950
(USA/Canada)
• EN60 950 (Europe)
• IEC60 950 (International)
• CB Certificate and Report
• IEC60 950 GS
Certification(Germany)
• GOST R 50 377-92 -
Certification (Russia)
• Ukraine Certification (Ukraine)
• CE - Low Voltage Directive
• 20 11/65/EU (Europe)
Emissions/Immunity
• FCC Part 15,Subpart B, Class A
• ICES-003: 2012, Class A
• CISPR22:2010, Class A
• EN 55022: 2010/AC:2011,
Class A
• EN 61000-3-2:2006+A2:2009
• EN 61000-3-3:2008
• EN 61000-6-4:2007+A1:2011
• RCM (Australia)
• VCCI Class A (Japan)
• MSIP KCC (Korea)
• BSMI CNS 13438:2006 95
(Taiwan)
• ANATEL Res. 442, Category
III (Brazil)
• CISPR24:2010
• EN 55024:2010
• MSIP KCC (Korea)
• EN/IEC 61000-4-2:2008
• EN/IEC 61000-4-3:2010
• EN/IEC 61000-4-4:2012
• EN/IEC 61000-4-5:2005
• EN/IEC 61000-4-6:2008
• EN/IEC 61000-4-11:2004
• FCC/ICES-003 - Emissions
(USA/Canada)
• CISPR 22 - Emissions
(International)
• EN55022 - Emissions (Europe)
• EN55024 - Immunity (Europe)
• EN61000-3-2 - Harmonics
(Europe)
• EN61000-3-3 - Voltage Flicker
(Europe)
• CE - EMC Directive 2004/108
EC (Europe)
• VCCI Emissions (Japan)
• AS/NZS 3548 Emissions
(Australia/New Zealand)
• BSMI CNS13438 Emissions
(Taiwan)
• GOST R 29216-91 Emissions
(Russia)
• GOST R 50628-95 Immunity
(Russia)
• Ukraine Certification (Ukraine)
• KC Certification (Korea)
• FCC/ICES-0 0 3 - Emissions
(USA/Canada) CISPR 22
-Emissions (International)
• EN550 22 - Emissions
(Europe)
• EN550 24 - Immunity (Europe)
• EN610 0 0 -3-2 - Harmonics
(Europe)
• EN610 0 0 -3-3 - Voltage
Flicker (Europe)
• CE - EMC Directive 20 0 4/10
8 EC (Europe)
• VCCI Emissions (Japan)
• AS/NZS 3548 Emissions
(Australia/New Zealand)
• BSMI CNS13438 Emissions
(Taiwan)
• GOST R 29216-91Emissions
(Russia)
• GOST R 50 628-95 Immunity
(Russia)
• Ukraine Certification (Ukraine)
• KC Certification (Korea)
• FCC/ICES-0 0 3 - Emissions
(USA/Canada) CISPR 22 -
Emissions (International)
• EN550 22 - Emissions
(Europe)
• EN550 24 - Immunity (Europe)
• EN610 0 0 -3-2 - Harmonics
(Europe)
• EN610 0 0 -3-3 - Voltage
Flicker (Europe)
• CE - EMC Directive 20 0 4/10
8 EC (Europe)
• VCCI Emissions (Japan)
• AS/NZS 3548 Emissions
(Australia/New Zealand)
• BSMI CNS13438 Emissions
(Taiwan)
• GOST R 29216-91Emissions
(Russia
• GOST R 50 628-95 Immunity
(Russia)
• Ukraine Certification (Ukraine)
• KC Certification (Korea)