Deployment Guide
Table Of Contents
- Table of Contents
 - Preface
 - About Extreme Campus Controller Deployment
 - Configuring DHCP, NPS, and DNS Services
 - Centralized Site with a Captive Portal
 - Centralized Site with AAA Network
 - Deploying a Mesh Network
 - Configuring an External NAC Server for MBA and AAA Authentication
 - Manage RADIUS Servers for User Authentication
 - External Captive Portal on a Third-Party Server
 - Access Control Rule Admin Portal Access
 - Deploying Centralized Web Authentication
 - Deploying ExtremeCloud IQ - SE as an External Captive Portal
- Deployment Strategy
 - Configuring an External Captive Portal Network
 - Editing the Configuration Profile for Network and Roles
 - Extreme Campus Controller Default Pass-Through Rule
 - Adding Extreme Campus Controller as a Switch to ExtremeCloud IQ - Site Engine
 - Editing the Unregistered Policy on ExtremeCloud IQ - Site Engine
 - Editing the ExtremeCloud IQ - Site Engine Profile for Policy and Location-Based Services
 
 - Deploying an ExtremeGuest Captive Portal
 - Deploying Client Bridge
 - Deploying an Availability Pair
 - Deploying Universal APs
 - Extreme Campus Controller Pair with ExtremeLocation and AirDefense
 - ECP Local Authentication
 - PHP External Captive Portal, Controller’s Firewall Friendly API
 - Index
 
Table 8: Mesh Device Settings (continued)
AP Model Option AP Behavior
• AP3xx
• AP4xx
• AP5xx
Tolerance Period This is a buer period (in seconds) between when
the metric value exceeds the Path Threshold and
the scan begins. Set the number of seconds to
allow the root path metric to recover before a scan
begins.
Valid values are 10-600. Default value is 60.
AP39xx Root • Yes - Mesh point is root node for this mesh
network.
• No - Mesh point is not a root node for this
mesh network.
Note: When using an AP39xx:
• When the AP39xx is a root AP, the Wireless
Distribution System (WDS) service is the
parent.
• When the Path Selection Method is snr-leaf or
mobile-snr-leaf, the WDS service is a child.
• In all other cases, WDS service is both a parent
and a child.
AP39xx Only Path Selection Method Select the method used for path selection in a
mesh network. Available options include:
• Uniform – The path selection method is
uniform (two paths are considered equivalent
if the average value is the same for these
paths). Use this method for regular
infrastructure meshing.
• SNR-Leaf – Use this method in special
infrastructure cases when it is more desirable
to make path decisions based on SNR than on
metric values.
AP39xx Only Hysteresis Minimum Threshold This is the minimum SNR value to consider a
candidate for the next hop in a dynamic mesh
network. For the AP39xx, this value maps to the
Roaming Threshold value.
• 100dB to 85dB maps to Low
• 84dB to 70dB maps to Medium
• 69dB to 0dB maps to High