User's Guide

Table Of Contents
Table 35: iBeacon IoT Settings (continued)
Parameter Description
Minor Identifies an individual beacon. Used to more precisely pinpoint
beacon location. This value complements the UUID and Major
values to provide more granular identification of a specific
location, such as a particular shelf, door-way, or item. Valid
values are 0 to 65635.
Specify 0 for Random Minor. Extreme Campus Controller
generates the Minor value. This ensures that each AP receives a
unique value.
This setting can be defined for a specific AP. For more
information, see Advanced Setting Overrides on page 196.
Measured RSSI The calibrated (or measured) RSSI, in dBm for the beacon. The
transmitted beacon includes this value in the tag. Default
values are: iBeacon -47dBm, Eddystone beacon -5dBm. The
default precision value is acceptable in most cases. To calibrate
your own precise value: Using Eddystone Beacon, measure the
actual transmitter output from 1 meter away and add 41dBm.
(41dBm is the signal loss that occurs over 1 meter.) If you are
using Apple iBeacon, refer to: "Calibrating iBeacon" at https://
developer.apple.com/ibeacon/Getting-Started-with-
iBeacon.pdf
This setting can be defined for a specific AP. For more
information, see Advanced Setting Overrides on page 196.
Related Topics
iBeacon Scan Settings on page 152
Eddystone-url Beacon Settings on page 153
Eddystone-url Scan Settings on page 154
Advanced Setting Overrides on page 196
iBeacon Scan Settings
Table 36: iBeacon Scan Settings
Field Description
Application Determines application type. Select iBeacon Scan.
Destination IP Address IP address of the customer Application Server that receives the
beacon report.
Destination Port Destination Port on the customer Application Server that
presents the beacon report.
Scan Interval Determines how long to wait between scans. Valid values are:
Min (100ms) and Max (10240ms). The default value is Min
(100ms).
Scan Window Determines how long to scan per channel. Valid values are Min
(100ms) and Max (10240ms).Value must be less than Scan
Interval value. Default value is 100ms.
Add or Edit a Configuration Profile Configure
152 Extreme Campus Controller User Guide for version 5.46.03