Configure a separate IoT profile for each IoT application:
1. Specify a profile name.
2. Select the IoT application.
The resulting parameters depend on the application you select.
Related Topics
Add or Edit a Configuration Profile on page 122
iBeacon Settings on page 151
iBeacon Scan Settings on page 152
Eddystone-url Beacon Settings on page 153
Eddystone-url Scan Settings on page 154
iBeacon Settings
Table 35: iBeacon IoT Settings
Parameter Description
Application Determines application type. Select iBeacon
Advertising Interval The advertising interval for the beacon application. Valid values
are: Min (100ms) and Max (10240ms). The default value is Min
(100ms).
UUID Identifier used to dierentiate a large group of related beacons.
A company can have a network of beacons with the same
UUID.
Major Identifies a subset of beacons within the larger set. This value
could represent a venue specific attribute, such as a specific
store or wing in a building. Valid values are 0 to 65535.
This setting can be defined for a specific AP. For more
information, see Advanced Setting Overrides on page 196.