Installation guide

Installing Optional Features
Consolidated "e" Series Hardware Installation Guide 93
Figure 31: Fitting the mounting bracket
5 Repeat steps 2 through 4 for the other side of the EPS-T.
6 Insert the EPS-T into a 19-inch rack.
CAUTION
Do not attach the AC power cord to the EPS-160 until it is properly mounted in the EPS-T (that is
properly grounded) and after the redundant power supply cable is connected.
7 Connect the keyed-end of the redundant power supply cable to the EPS-160. The key is a plastic tab
on the cable connector housing that fits into the chassis to ensure correct alignment of the connector.
See Figure 32 for details on the connector key and Figure 33 to locate the connectors on the EPS-160
and the switch. Table 20 gives the wire-to-pin connections for the connector on the rear panel of the
EPS-160.
NOTE
The cable length is 1 meter.
Figure 32: Redundant Power Cable with Key
ES4K026
ES4K027