Installation guide
50 Consolidated "e" Series Hardware Installation Guide
Summit 300 Switch Overview
NOTE
See “Evaluating and Meeting Mini-GBIC Requirements” on page 31 for information about supported
mini-GBIC types and distances.
LED Behavior
The light emitting diode (LED) behavior for the Summit 300-48 is shown in Figure 11.
Table 11: Summit 300-48 switch LED behavior
Unit Status LED (MGMT LED)
Color Indicates
Blinking Green
Solid Amber
Off
The Summit switch is operating normally.
The Summit has failed its POST.
No power.
Power Supply Status LEDs (per power supply)
Color Indicates
Solid Green
Solid Amber
Off
The power supply is operating normally.
There is a fault.
There is no power.
Fan Unit Status LEDs
Color Indicates
Solid Green
Solid Amber
Off
The fan is operating normally.
There is a fault.
There is no power.
Power Supply Status LEDs
LED Color Indicates
OUT Solid Green
Off
The output voltages are enabled and within specification.
There is a fault on at least one output voltage or voltages are out
of specification.
TEMP Solid Amber
Off
The fan failed or there is an over temperature condition.
The fan is operating normally and operating temperature is within
limit.
IN Solid Green
Off
The input voltage is within specification and the input section is
working.
The input voltage is out of range or there is a fault in the input
section.