Installation guide
100 Consolidated "e" Series Hardware Installation Guide
Safety Information
• Operate the unit and attached equipment under Safety Extra Low Voltage (SELV) conditions. The “e”
series of switches operate under SELV conditions according to the IEC 950 standard. The conditions
are only maintained if the equipment to which it is connected also operates under SELV conditions.
• Ensure that the appliance coupler (the connector to the unit and not the wall plug) has a
configuration for mating with an EN60320/IEC320 appliance inlet.
• France and Peru only
Do not attempt to power the switch from IT† supplies. If your supplies are of IT type, the switch
must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary
connection point labeled Neutral and connected directly to ground.
Power Cable
Use an AC power cable appropriate for your country. Check your local electrical codes and regulatory
agencies for power cable requirements. The countries listed below have the following additional
requirements:
• USA and Canada
— The cable set must be UL-listed and CSA-certified.
— The minimum specification for the flexible cable is No. 18 AWG (1.5 mm
2
), Type SVT or SJT,
3-conductor.
— The cable set must have a rated current capacity of at least the amount rated for each specific
product.
— The AC attachment plug must be an Earth-grounding type with a NEMA 5-15P (10 A, 125 V)
configuration.
• Denmark
— The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
• Switzerland
— The supply plug must comply with SEV/ASE 1011.
• Argentina
— The supply plug must comply with Argentinian standards.
NOTE
When using dual power supplies, make sure that each AC power supply attaches to an independent
power source.
Optical Safety
Fiber Optic ports. To protect your eyes, never look at the transmit LED/laser through a magnifying
device while it is powered on. Never look directly at a fiber port on the switch or at the ends of fiber
cable when they are powered on.
This is a Class 1 laser device. Use only devices approved by Extreme Networks.