Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
99
PD4-1601047171,
PD4-1598240578
STP crashes when making topology changes to a domain name containing more than 29
characters.
Workaround: Use STP domain names that are less than 30 characters.
PD4-1530467581,
PD4-1535593829
An untagged packet that is size 1,518 and ingressing an 8900-G48X-xl module is getting
slowpath L3 forwarded.
PD4-1424690937,
PD4-805462597
A slot fails on a BlackDiamond 8800 series switch when enabling dot1p examination
inner-tag ports on more than 24 ports in a vMAN.
PD4-1518161071,
PD4-1521499552
L2 traffic ingressing a 10G8X-xl I/O module for a MAC that is learned in another slot
(G48Tc) is being dropped in some cases.
BlackDiamond 10800 Switch
PD4-1641608989,
PD4-1108500108
On a BlackDiamond 10800 switch with dual MSMs and a G20X module, CLEAR-Flow
delta rules may be triggered on the backup MSM when not needed.
PD4-1586364429,
PD4-1566158665
On a BlackDiamond 10800 series switch, an MSM failover results in too many SNMP
traps (extremePortMauChangeTrap) being sent.
PD4-1272650041,
PD4-804225168
ESMI related warning messages are seen in the output of the show log command
whenever an SSL certificate with a key length of 4,096 is created or the HTTPD process
is restarted.
PD4-1215941529,
PD4-1035637713
Fans on a BlackDiamond 10800 switch may run at a higher RPM, causing unacceptable
noise levels.
BlackDiamond 12800 Series Switch
PD4-1598681891 When a BlackDiamond 12800 series switch is transmitting EAPS traffic, a dual master
situation occurs and the backup MSM goes into a failed state causing the system to
reboot with a higher number of routes and traffic. This issue is no longer reproducible.
BlackDiamond 20800 Series Switch
PD4-1026932011 Hot swapping an XFM module may cause an odometer reading error. ExtremeXOS will
not be able to read the odometer reading.
FABRIC-2 information:
State: Operational
PartInfo: XFM-2 10076-80022 806019-00-05
Revision: 5.0
FailureCode: 0
Odometer:
Temperature: 40.0 deg C
Status: FABRIC Mode
PD4-1300795581 IP fragmentation is not happening with jumbo frame enabled.
PD4-1230894831 When installing the EXOS image, watchdog EPC (csd_flag_wait+0x18/0x28) will happen
and may cause a crash.
Workaround: Stop traffic when installing new ExtremeXOS image.
PD4-1527934161,
PD4-1522821191
A BlackDiamond 20800 series switch crashes when a new VLAN translation member
VLAN is added. The system appears to run out of multicast/flooding PSI resources.
PD4-1438460992,
PD4-1402199417
While running diagnostics on a BlackDiamond 20800 series switch with an XM-8XB
module in slot 2, and only one XFM-1 in slot 1, the output of the run diagnostics
command shows the following error.
Diag Version=1.0.1.7. Exos Version=12.4.1.7 S/N=09366-80141
System Test |
FABRIC Connectivity: Device 3 Link 19 Failed
PD4-1265032583,
PD4-1235317131
Running the show access-list counter command on a BlackDiamond 20800
series switch causes a buffer leak, which results in a slot failure and conduit error.
Table 45: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description