Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
97
Resolved Issues in ExtremeXOS 12.5.1
The following issues were resolved in ExtremeXOS 12.5.1. ExtremeXOS 12.5 includes all fixes up to and
including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.5, ExtremeXOS 12.2.2,
ExtremeXOS 12.3.4, and ExtremeXOS 12.4.2. For information on those fixes, see the release notes for the
specific release.
Table 45: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD3-71725881 When configuring an optional name for the time zone/DST, the time zone name
truncates at seven characters. The system default is six characters.
PD4-1578876668,
PD4-1544849931
In some cases, the netTools process may die with signal 11 while processing DNS
responses.
PD4-1571416791,
PD4-1562364701
When the udp-profile is used to forward traffic to a destination-ipaddress, a memory leak
is observed in ip_dst_cache.
Workaround: Use udp-profile to forward packets to a VLAN instead of a destination IP
address.
PD4-1571416791 When the udp-profile is used to forward traffic to a destination-ipaddress, a memory leak
is observed in ip_dst_cache.
PD4-1554296001 When ISID is not added as an intermediate point, and is the ingress or egress port,
LTMs are dropped.
Workaround: Add ISID as a MIP.
PD4-1194741135 setDynamicAc.pl, which is used to create a dynamic ACL and bind it to a specific port, is
not working.
Workaround: The following SOAP element corrects this issue.
SOAP::Data->name("applicationName" => "Cli"));
PD4-1676377057,
PD4-1446804247
Multicast traffic is showing the incorrect dot1p replacement for CPU (slowpath) forwarded
packets with TOS bits set at 7.
PD4-1636210325 The following error message is displayed after running the ping command and abruptly
closing 10 or more Telnet/SSH sessions.
Error: Too many concurrent ping requests.
PD4-1507616001,
PD4-1301482701
ELSM is not responding after rebooting a switch, resulting in the links of neighboring
devices staying down.
Workaround: After rebooting the switch, run the enable elsm ports <port-list>
command again.
PD4-1578876722,
PD4-1491778548
snmpSubagent process crashes with signal 11 when creating a row in the pingCtlTable
with a pingCtlTestName length greater than 32 bytes.
Workaround: Use pingCtlTestName with a length less than 32 bytes.
PD4-1600819459,
PD4-1323337281
When copying and pasting a CLI command that begins with a bullet, the cliMaster
crashes with signal 11 when the bullet is included as part of the command.
PD4-1593572153,
PD4-1374774272
When using ISIS, you cannot set a metric value as 0 for export routes.
PD4-1585125619,
PD4-941257511
Slowpath traffic may cause SNTP packets to experience delayed processing on an
ExtremeXOS switch and generates the following error message:
<Noti:DM.Notice> Slot-1: Setting hwclock time to system time, and
broadcasting time