Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
96
IGMP
PD4-1757733744,
PD4-1453474837
IGMP membership query packets are seen on a port when IGMP is disabled but IGMP
snooping is enabled. To resolve this issue, run the disable igmp proxy-query
vlan <vlan-name> command.
MPLS
PD4-1704766794,
PD4-1687280681
IP multicast packets received on a service vMAN/VLAN may not be flooded through a
VPLS tunnel.
Workaround: Add the service vMAN/VLAN port to any IGMP snooping enabled VLAN and
delete the port from that VLAN. For example:
configure vlan default add port 21 tagged
configure vlan default del port 21
PD4-1660127877 When MPLS PHP is enabled on a label edge router, LSP does not go through if the
BlackDiamond 8800 series switch is an LSR.
OSPF
PD4-1841878451,
PD4-1524171924
Not all of the AS external routes in OSPF are getting installed in the route table.
ScreenPlay
PD4-1846363955,
PD4-1821932411
The following directories are viewable in a browser window when Web HTTP is enabled:
/scripts
/images
/assets
/com
SNMP
PD4-1660318270,
PD4-1395832491
The SNMP query for the OID "extremePowerSupplySerialNumber" always returns an
error.
PD4-1700317091,
PD4-1598272292
The snmpMaster process crashes with signal 11 on NULL pointer access.
PD4-1700317212,
PD4-1328651560
The CLI command disable snmpv3 user default-user does not disable default
user access.
VRRP
PD4-1675307605,
PD4-1664819101
VRRP gateways may get stuck in a dual master state when VRRP is run on a secondary
IP falling under the same address class as the primary, but in a different subnet.
Table 44: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description