Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
93
PD4-1820555257,
PD4-966386662
Local multicast packets (packets destined for a well known reserved multicast address
such as 224.0.0.x) are flooded in hardware for BlackDiamond 8800 series and Summit
family switches.
PD4-1771736843 The xmld process crashes with signal 6 when opening a SOAP session using a session
ID larger than 64 characters.
PD4-1764118037 A switch continues to try to bind configured LDAP servers in a loop if the configured
LDAP servers are not reachable in a network.
PD4-1859525697,
PD4-1847511220
When running the SSH process (exsshd), CPU usage is excessive and some SSH
sessions are not cleared.
PD4-1838462545 When ELSM detects a link down, ELSM does not deactivate the port.
PD4-1813267547,
PD4-1239811496
Deleting a VLAN does not cleanup route entries learned by RIP through the VLAN.
PD4-1823016095,
PD4-1090889907
High CPU utilization messages are not logged while SNMP traps are sent.
PD4-1819371657,
PD4-896535258
When a banner configuration file stored in a Windows environment is loaded, the banner
configuration is not restored properly.
Note: After unconfiguring a switch, the system banner message cannot be restored using
a saved configuration.
Workaround: Reconfigure the banner message.
PD4-1851589182,
PD4-1323337297
A switch will experience memory depletion due to HAL process when sending L2 traffic
to a PVLAN with continuous SA increment.
PD4-1758919460,
PD4-1517323275
The SSH process (exsshd) consumes 99% of CPU usage when running the clear
session command after abruptly closing an SSH session (xterm client only).
PD4-1481490491 Using a dual MSM device, network policy files are not downloaded to a backup MSM
because, in a failover scenario, VM tracking authentication does not work until
completion of the repository synchronization.
PD4-1741718214,
PD4-1107340401
When TACACS is used for user authentication, the log message shows the wrong IP
address of the user being authenticated.
PD4-1679413117,
PD4-1677893691
A telnet connection may be abruptly closed by a switch when multiple telnet connections
are consecutively initiated in a short period of time.
PD4-1703399298,
PD4-962149281
The output for the show configuration etmon | detail command does not
show the disabled sFlow port.
PD4-1738654762,
PD4-1738654681
ExtremeXOS software does not correctly recognize the following mini-GBIC modules:
100FX/1000LX dual speed SFP, part number 4050-00020-02
100FX SFP, part number 4050-00030-03
PD4-1649655687,
PD4-1417613295
The help text for the configure fdb vpls agingtime command displays the wrong
possible values.
PD4-1675097007,
PD4-1081411076
The CLI allows RIP configurations for L2 VLANs. After completing a RIP configuration,
running the show rip interface command causes the RIP process to die with signal
11.
PD4-1758727670,
PD4-1695304439
After configuring an EMS xml-notification target, the name of the target is not included in
the output of the show configuration command.
PD4-1601514363 Using IdMgr, when running the clear iparp
command or disabling IdMgr globally, an
ACL/policy applied for a MAC-based identity is not correctly removed from the DUT,
causing stale ACLs to remain in the DUT.
PD4-1575174331 With IdMgr enabled, an LDAP search fails for a dot1x client using EAP-TLS or EAP-
PEAP-certificate authentication. This causes a dot1x identity to remain in the
authenticated role even though the user configured role exists in the DUT for this
identity.
Table 44: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description