Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
90
PD4-1957143110,
PD4-1034683284
You cannot load a script using a flow-redirect configuration when a VLAN is down.
Workaround: Enable the VLAN and reconfigure the flow-redirect configuration.
PD4-1947222056,
PD4-1937692011
Copying large configuration files through SCP fails.
PD4-1917632030,
PD4-1857823251
A mismatch between a PIM multicast cache and a hardware binding results in traffic loss.
PD4-1923713613,
PD4-1820757911
If remote mirroring is configured using an EAPS primary port, EAPS is disabled when the
switch reboots.
PD4-1877910031 After changing the VPWS service VLAN tag, the change does not take effect.
Workaround: Delete and re-add the VPWS.
PD4-1866206193,
PD4-1299135401
Multicast traffic is dropped with an EAPS shared port configuration during an EAPS
topology change.
PD4-1835754705,
PD4-1177495965
XML API allows a user to create several VLANs using the same VLAN tag.
PD4-1813024595 The show configuration ip-fix command does not return a configured flow-key if
you only configure src-ip/dest-ip. It also removes the non-IP flow-key.
PD4-1887144137,
PD4-1155806118
When an unknown vendor ID is sent in a RADIUS accept packet, the log message does
not print the unknown vendor ID.
PD4-1897494489,
PD4-1887057001
Running the configure flow-redirect <redirectname> no-active/health-
check command resets a configured VR to a VR-Default.
Workaround: Run the configure flow-redirect <redirectname> vr command
after configuring the configure flow-redirect <redirectname> no-
active/health-check command.
PD4-1909443376,
PD4-913229871
API queries for RADIUS and TACACS do not return any values. Set is working properly,
but a get returns empty.
PD4-1933226667,
PD4-1933225935
The ACL action "copy-cpu-and-drop" is not copying EAPS control packets to the CPU.
PD4-1867264398 Running the save configuration command on an ExtremeXOS switch with a dual
MSM, or a stack with a backup node, causes a memory leak in the CfgMgr process.
PD4-1874010052,
PD4-1601514286
A switch does not generate IdMgr XML notifications to a Web server when disabling
IdMgr globally.
BlackDiamond 8800 Series Switch
PD4-1806034261 Process snmpSubagent is terminated with signal 6 when clearing a counter after setting
an SNMP session.
PD4-1921505342,
PD4-1548261276
On a BlackDiamond 8800 series switch, traffic is not being redirected by the primary
LACP port when the secondary MSM with secondary ports is rebooted on LACP during a
process kill.
PD4-1899757948,
PD4-1873304831
ECMP related error messages are seen on BlackDiamond 8800 series switches when
enable iproute sharing and LAG are configured on the switch.
BlackDiamond 20800 Series Switch
PD4-1905529131,
PD4-1536990491
When a BlackDiamond 20800 series switch is an EAPS master, port QP1 increments
instead of port QP8.
Summit Family Switches
PD4-1879276738,
PD4-1506829269
On Summit family switches, ethernet loopback tests fail when running extended
diagnostics without an active management port.
PD4-1910625750 Leaving a setup running overnight on a Summit X480 switch causes memory depletion.
Table 41: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description