Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
89
Resolved Issues in ExtremeXOS 12.5.3
The following issues were resolved in ExtremeXOS 12.5.3. ExtremeXOS 12.5 includes all fixes up to and
including ExtremeXOS 11.1.4.4, ExtremeXOS 11.2.3.3, ExtremeXOS 11.3.4.5, ExtremeXOS 11.4.4.7,
ExtremeXOS 11.5.2.10, ExtremeXOS 11.6.5.3, ExtremeXOS 12.0.5, ExtremeXOS 12.1.6, ExtremeXOS 12.2.2-
patch1-12, ExtremeXOS 12.3.5, and ExtremeXOS 12.4.3-patch1-8. For information on those fixes, see the
release notes for the specific release.
Spanning Tree Protocol
PD4-2012749890,
PD4-1780972901
Renaming a VLAN and deleting the STP domain to which it has an auto-bind relation,
auto-binding it to a new STP domain displays the following error:
Error: Cannot enable auto-bind for vlan v2 to STP domain s2, it
is the carrier vlan of STP domain s1
PD4-2094536435,
PD4-2093639778
After making STP configuration changes on a switch, RSTP root bridges send hello
BPDUs every 4 seconds when the switch is configured for every 2 seconds.
Table 41: Resolved Issues, Platform-Specific and Feature PDs
PD Number Description
General
PD4-1981255904,
PD4-1229634794
LACP packets are corrupted if the master port is mirrored on a SummitStack.
PD4-1971710345,
PD4-1776441950
Software-controlled redundant ports may cause loops if a port is configured for
redundancy after it is associated with an existing VLAN.
PD4-1963014357,
PD4-1409846531
The icmp-type match condition for ICMPv6 is not supported on Summit family and
BlackDiamond 8800 series switches.
PD4-1963014296,
PD4-1688446379
FDB entries learned via LAG are not included in the output of the show fdb stats
ports all command.
PD4-1981933655,
PD4-1374774241
The SNMP OID extremeCurrentTemperature does not return the current temperature of a
switch. This is also seen when accessing the switch using ScreenPlay.
PD4-1986104343,
PD4-1933787279
The Node Manager process consumes excessive CPU usage on a backup MSM when
the system uptime reaches 994 days.
PD4-1981365232,
PD4-1870786111
Running the disable netlogin port <slot:port> command while the slot is
down causes the switch to drop the packets received on that port in hardware if the
ethernet-source-address is not learned. This affects EAPSv1 control packets because the
ethernet-souce-address in the EAPSv1 control packets is a special MAC and will never
be learned.
PD4-1924562736 Enabling SSH using a license file fails with a warning message but an SSH key is
generated anyway.
PD4-1874010041 A switch does not generate a "Remidfrmport" UPM event when disabling IdMgr globally.
PD4-1937052478 Telnet access profiles are blocking all IPv6 telnet connections.
PD4-1953112031 An NVPP policy file in a switch is not in sync with the repository policy file whenever
there is a change in the repository policy file.
Workaround: Create a new policy file containing the information in the old policy file.
PD4-1686001001 Running RIPng on 6in4 tunnels generates the following error message:
<Erro:Kern.Error> async queue is growing
Table 40: Resolved Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description