Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
79
PD4-749682632 You cannot run the configure port auto on command on XGM2-2bt ports.
PD3-127401831 On a Summit X250e platform with 128 VRRP instances that are advertised for 100
milliseconds, the feature "don't preempt" is not working properly.
PD4-427423116 When a dot1x client is authenticated at multiple VLANs, the output of the show
netlogin port command shows the client is sometimes authenticated at the local
server and other times at a RADIUS server.
Note: This occurs when dot1x and MAC authentication are enabled on the port.
PD4-1142692318 On Summit X480 switches, L3 multicast traffic sent from a service VLAN/vMAN to VPLS
is not received at the VPLS peer.
Workaround: When VPLS enabled VLANs exist on a port, all VLANs on that port must
have IGMP snooping disabled. Also, the IP address cannot be configured on any other
VLANs (including non-VPLS VLANs). Remove ports from the default VLAN.
PD4-448681226 The show l2stats command does not count ARP packets to the CPU, even though
the packet goes to the CPU.
PD4-489142320 One Gigabit ports set to auto on flap twice during a switch reboot.
PD4-489359602 Conflicting Link Fault Signal (LFS) alarms are shown when disabling local ports.
PD4-274249122 If a Summit switch populated with an XGM2-2bt module is rebooted, a false link up is
seen on 10G links connected to the XGM2-2bt ports approximately 30 to 50 seconds
before the switch has fully booted.
PD3-43606168 If sFlow does not have a collector configured using the configure sflow
collector command, the show log command generates the following messages:
08/23/2005 12:28:09.55 <Noti:sflow.debug.AddCntSmplFail> : Could
not add the counter sample for port 0:1020, as receiver is not
configured.
08/23/2005 12:07:49.55 <Noti:sflow.debug.AddCntSmplFail> :
Previous message repeated 61 additional times in the last 1200
second(s).
PD3-40266236,
PD3-40233121
Traffic on load share ports configured as redundant ports incorrectly moves to other ports
in the load share group during link transition.
PD3-202013281 Learning is disabled by default on remote mirroring VLANs. Running the enable
learning command on those VLANs may cause a loss of remote mirrored traffic.
SummitStack
PD4-2137369837 Identity information between a switch and Ridgeline does not sync up when globally
disabling and enabling IdMgr. Ridgeline shows some identities as active users, but the
switch shows no identities.
PD4-1629045810 When booting up a SummitStack, the following error message is displayed:
<Erro:cm.sys.actionErr> Slot-1: Error while loading "ports":
Speed change is not allowed on port 6:49 as it is a Trunk member
port.
PD4-1908119150 A SummitStack does not use the MAC address of the stack for ARP replies when
communicating with other devices.
PD4-1467634651 The output for the show version command does not include VIM and PSU on the
master node, and the PSU version of the backup node.
PD4-1678164933 After upgrading to ExtremeXOS 12.5.1.4, the following error is shown in the log:
<Erro:Kern.IPv4Mc.Error> Slot-1: Unable to Del IPmc vlan 924 for
1:15 s,G=a9e6f05,e1010028 IPMC 186, unit 0 Entry not found.
PD4-1701480101 A system crash occurs at EPC c2bd6d94 _bcm_fb_cosq_config_set during a regression
run of EPM.
Table 38: Open Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description