Specifications

Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
77
PD4-847978862 A monitor port does not come up after enabling a port after a DUT is rebooted with a
disabled monitor port. The following error is displayed while rebooting:
MM-A: voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
08/15/2009 16:47:02.47 < Erro:HAL.Card.Error > MM-A:
voyagerCardPowerEnabl
e:1144:- Invalid System mode information returned from dm.
dmGetSystemMode
() = 33
PD4-803757411 Configuring a meter on a BlackDiamond 20808 switch to limit broadcast or multicast
traffic (rate-limit flood-traffic) is not possible without an HQoS license.
PD4-748388236 Egress rate shaping does not work after running the save and reboot commands if an
egress port is not specified. Configured egress rate-shaping does not work on a newly
inserted I/O module if an egress port is not specified.
Workaround: Unconfigure the ACL and re-apply the same ACL.
PD4-715473099 The multicast traffic receive rate for 10,000 multicast groups takes an excessive amount
of processing time.
PD4-756263261 The show fabric command in an ExtremeXOS environment shows the fabric
information is XFM-2.
PD4-728354005 On a BlackDiamond 20808 switch, running the show tech-support command when
I/O modules or fabric slots are in the process of booting, or are otherwise not
operational, may cause sys-health-check output to display fabric link faults, when
there are actually none. This is a transient state. Once the modules are operational, only
actual fabric link faults are displayed in the command output.
PD4-603229266 A slot reboots when load sharing is disabled and MVR is disabled and re-enabled.
PD4-587169451 Running the install firmware command may generate numerous error messages in
the Event Management System (EMS) logs. These messages do not impact system
performance.
<Erro:HAL.Sys.BackupPFCFailed> MM-A: Backup Power Fan Controller
(#2) has failed
<Erro:EPM.Upgrade.Fail> MM-A: Upgrade failed, script: install
bootrom failed
<Erro:HAL.Sys.GetPFCMastershipFailed> MM-A: Failed to get Power
Fan Controller Mastership for slot #17
<Erro:HAL.Sys.OtherPFCFailed> MM-B: Power Fan Controller in slot
17 has failed to communicate with EXOS
<Erro:HAL.Sys.SetBackupPFCToMaster> MM-B: An error happened and
is now setting the backup Power Fan Controller #2 to be the
master Power Fan Controller
<Erro:HAL.Sys.MasterPFCFailed> MM-B: Master Power and Fan
Controller (#1) has failed
<Crit:HAL.Fabric.Critical> MM-A: pioennerBringDownFE200 Bringing
Down FE200 on XBAR 1 as the command EXTRUC_FE_READ_CMD Failed,
Reason: UCPIPE_ERROR
<Erro:HAL.Sys.Error> MM-A: Slot XBAR1: 23918 FE 0 read 0xb50
Summit Family Switches
PD4-2012749818,
PD4-1437616911
When running the configure ports medium <fiber/copper> auto <on/off>
speed <speed> duplex <half/full> command, the command is not retained
when a switch reboots.
PD4-1914383901 Traffic for a multiport FDB entry sent from one port is not received on the other port.
Table 38: Open Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description