Specifications
Open Issues, Known Behaviors, and Resolved Issues
ExtremeXOS 12.5.4 Release Notes
70
PD4-723933144 After adding a sub-VLAN to a super-VLAN on a Summit X450 switch, the following
message is displayed:
<Erro:HAL.IPv4ACL.Error> : ACL filter hardware full for unit 1
PD4-2110742669 When using SCP to transfer files to an Extreme switch, the transfer fails with an
"incomplete command" error.
PD4-2112303228 An ELRP loop occurs after rebooting a Summit X450e-48p stack because of a delay in
EAPS convergence.
PD4-2011056021 After a reboot, I/O slots do not go into an operational state with identity management
enabled (when I/O ports are part of identity manager).
Workaround: Using the ExtremeXOS CLI, run the configure identity-management
delete ports all command before the switch reboots. Once the switch has
rebooted, run the configure identity-management add ports all command.
PD4-1933787334 The RtMgr process may encounter the assertion failure ASSERTION FAILURE by
rtmgr in rtMgrResolveEgressIf()@rtMgrTable.c:6892 REASON:
IPGW_OUTIF_INDEX(tmpInfo) == ifIndex when an IP address is configured on a
VLAN.
PD4-1922513168 EPM process crashes with signal 6 when upgrading a switch from ExtremeXOS 12.2.2 to
ExtremeXOS 12.3.5 when an SSH license file has 100 or more SSH licenses.
PD4-1885807081 A switch shows the following ACL error while detecting a kerberos identity and the switch
is not synchronizing the kerberos identity with a backup slot.
<Erro:HAL.IPv4ACL.Error>
PD4-1859776249 A switch resends SNMPv3 Inform Requests even after an SNMPv3 Inform Response is
received from an Inform receiver.
PD4-1842342791,
PD4-1291631579
When working in network login, after a dot1x client logs out, the port is not moved to a
MAC-based VLAN.
PD4-1842342743,
PD4-1300978095
After installing a legacy CLI module, the CLI command load script returns the
following error message:
%% Unrecognized command: create vlan v$x
PD4-1824530443 The following behavior differences were observed between a Summit X480 and a
Summit X450a switch:
• Configured a general query interval of 125 seconds but a Summit X480 switch sends
general queries every 130 seconds. This issue is not seen on a Summit X450a
switch.
• A Summit X480 is sending both MLDv1 and MLDv2 reports even though only MLDv2
is enabled. This issue is not seen on a Summit X450a switch.
PD4-1799324137 Co-existence of untagged vMAN VPLS and VLAN VPLS on LAG ports is not supported.
PD4-1687877821 A switch hangs while adding 52 RIPng processes to a user VR with eight processes
already in the default VR.
PD4-1620486150 A netTools configuration is lost after a graceful termination of the netTools process
followed by an MSM failover.
PD4-1630086252 When unconfiguring an IP address on an egress VLAN, or re-configuring the IP address
of the egress VLAN, all the MVR cache entries that are ingressing via other VLANs are
also cleared from the hardware. Because of this, momentary CPU bursts are observed.
PD4-1659204361,
PD4-772121565
A HAL crash with signal 11 occurs when running the disable access-list
refresh blackhole command.
PD4-1663984367 Whenever a (*, G) join is received, all hardware entries installed on non upstream
interfaces (*, G) are cleared. Therefore, every 60 seconds, the L2 switching is affected,
traffic comes to the CPU, and entries are re-learned.
Table 38: Open Issues, Platform-Specific and Feature PDs (Continued)
PD Number Description