The BlackDiamond 6800 switch is suited for use in a wiring closet or equipment room,
where it can be mounted in a standard 19-inch equipment rack. Mounting brackets are
integrated with the chassis.
When deciding where to install the BlackDiamond 6800 switch, ensure that
The switch is accessible and cables can be connected easily.
Water or moisture cannot enter the chassis.
Air-flow around the unit and through the vents at the front, side, and rear of the
chassis is not restricted. A minimum of 3 inches is required (5 inches recommended)
for clearance.
Temperature operating limits of 0° to 40° C are not exceeded.
I
NSTALLING
THE
B
LACK
D
IAMOND
6800 S
WITCH
The BlackDiamond 6800 switch can be mounted in a rack. The chassis is 15U high and
fits in most standard 19-inch racks.
The BlackDiamond 6800 chassis is shipped empty; you must install the power supply
and modules after rack-mounting the empty chassis.
Warning: Rack-mount the chassis before installing any BlackDiamond 6800
switch components.
To install the BlackDiamond 6800 switch, follow these steps:
1
Mount the helper bracket in the rack using four appropriate rack-mounting screws,
as shown in Figure 2-1.