User guide
3-2 B
LACK
D
IAMOND
U
SER
G
UIDE
C
ONFIGURING
S
LOTS
AND
P
ORTS
For information on saving the configuration, refer to Chapter 13.
You can configure the BlackDiamond with the type of I/O module that is installed in
each I/O slot. To do this, use the following command:
config slot <slot> module [f32t | f32f | g4x | g6x]
You can also pre-configure the slot before inserting the module card. This allows you to
begin configuring the module and ports before installing the card in the chassis.
If a slot is configured for one type of module, and a different type of module is inserted,
the inserted module is put into a mismatch state, and is not brought online. To use the
new module type in a slot, the slot configuration must be cleared or configured for the
new module type. To clear the slot of a previously assigned I/O module type, use the
following command:
clear slot <slot>
All configuration information related to the slot and the ports on the module is erased.
If a module is present when you issue this command, the module is reset to default
settings.
To display information about a particular slot, use the following command:
show slot <slot>
Information displayed includes the following:
• Card type, serial number, part number
• Current state (power down, operational, diagnostic, mismatch)
• Port information