User's Manual

ExtremeWireless 802.11ax AP460i/e Outdoor
Access Points
AP460i/e Overview
The AP460i/e access points are outdoor model enterprise class 802.11ax access points.
The “i” in AP460i indicates that the access point comes with internal antennas and the “e”
indicates that it comes with external antenna connectors. The access points feature a
dual-band radio, two band-locked radios, eight WiFi internal or external antennas, and
one Bluetooth Low Energy (BLE) antenna.
The AP460i/e can be mounted on a flat surface such as a wall or to a pole.
The AP460i/e access points have the following features:
Radios:
Three 802.11ax radios (one 2X2 2.4GHz radio, one 4X4 5GHz radio, and one 2X2
2.4GHz and 5GHz radio)
One IoT Radio (2.4 GHz)
Console port: RJ45
Two Ethernet ports:
1 x 100/1000/2500 Mbps auto-negotiation Ethernet port, RJ45
1 x 10/100/1000 Mbps auto-negotiation Ethernet port, RJ45
LEDs: Seven
All LEDs will be on during reset and connect to general-purpose input/output
(GPIO) pins
One reset button
Power: PoE 802.3af (see
Table 1 for details)
Antennas:
Eight WiFi internal/external antennas
One BLE internal antenna on AP460i and one BLE external antenna port on
AP460e
Temperature:
-40° C to +60° C (-40° F to +140° F)
Enclosure: Plastic
Table 1 AP460i/e Power source
Figure 1 Front views of AP460i and AP460e
LED Indicators
The LED indicators are located on the front face of the access point but are not
visibly marked.
Table 2 AP460i/e LED indicators
AP460i/e Box Contents
Ensure that the following items are available:
Note: The AP460i/e requires a minimum base firmware of WiNG 7.3.0.
Power source Description
Power over Ethernet (PoE)
Power is provided through the RJ45 Ethernet ports of
AP460i/e, compliant to be powered with 802.3at and
802.3bt to provide full functionality. For reduced
functionality, use 802.3af.
LED indicator LED color Description
Status Green Normal operational status
Amber Non-operational status
GE1 Ethernet Amber 100 Mbps
Green 1000 Mbps
Purple 2.5G
GE2 Ethernet Amber 100 Mbps
Green 1000 Mbps
Radio 1 Green 2.4G activity
Radio 2 Amber 5G activity
Radio 3 White Sensor activity
IoT (BLE) Blue Indicates BLE is enabled
Table 3 Contents of the AP460i/e box
Quantity Item
1 AP460i/e Quick Reference
1 Access point (AP460i or AP460e)
Access Point Mounting Options
AP460i/e access points can be mounted on a wall or to a pole by purchasing separate
mounting brackets, which are described in the following table.
Table 4 AP460i/e Mounting Brackets Usage
All mounting brackets and accessories are sold separately. For detailed installation
instructions about all mounting procedures, refer to the ExtremeWireless Access Points
AP460i/e Installation Guide in the Extreme Networks Documentation Support site.
Install the Access Point
When you install the access point, the gore vent must be on the side closest to the ground
and not above the plastic cover. You must provide a 3-inch drip loop on all cables.
Use these instructions as guidelines to mount and connect the AP460i/e access points
easily and safely.
Install the Access Point on a Wall or a Flat Surface
Option 1: Install the Access Point to a Flat Surface Using the KT-147407-02
Flat Part and the 1-axis Tilt Part
The KT-147407-02 bracket has three bracket parts; flat part, 1-axis tilt part, and the pole
part.
1
Hardware bag:
One ground screw
One ring terminal
One star washer
Mounting
Bracket and
Part Number
Wall Install Pole Install Notes
KT-147407-02;
bracket;
comes with three
parts:
•Flat part
•1-axis tilt part
•Pole part
Yes Yes For attaching to a wall or a flat
surface, use the bracket part that
has two holes on the surface of the
metal portion; also called the flat
part. For attaching to a pole, if the
1-axis tilt is not required, attach the
pole part of the bracket to the
access point. If 1-axis tilt is required,
attach the pole part of the KT-
147407-02 bracket on top of the
second wall part.
KT-150173-01;
extension arm;
used with
KT-147407-02
bracket parts
Yes; use the
flat wall
mount part of
the KT-
147407-02
bracket
Yes; use the
pole mount
bracket part of
the KT-
147407-02
bracket or use
all three KT-
147407-02
bracket parts
The KT-150173-01 extension arm can
also be used by itself without the
other KT-147407-02 bracket parts.
MBO-ART02; 10 in.
2-Axis
articulating
mounting bracket
Yes Yes; attach the
MBO-ART02
articulating
mounting
bracket to the
WS-MBO-
POLE01
bracket
The wall must
be strong enough to
support the AP during
inclement weather.
WS-MBO-POLE01
bracket
No Yes; the
POLE01
bracket can
only be used
with the MBO-
ART02
articulating
mounting
bracket
If the pole diameter is >= 1 in.
(25.4mm), use small cable
clamp. If the pole diameter
is between 5 in. - 7 in. (178mm),
use large cable clamp. For
any other pole diameter,
provide your own stainless
steel cable clamp. The
band must be 0.5 in. (12.7mm)
wide.
WS-MBV-VMM
Vehicle Bracket
(#32216); comes
with
four parts
Yes No None
Note: The sensor and the BLE antennas come with dust caps on them. Do not
remove the dust cap until you need to install the antennas.
Electrical Hazard: Only qualified personnel should perform installation
procedures.
Table 3 Contents of the AP460i/e box
Quantity Item
Figure 2 KT-147407-02 bracket flat part and 1-axis tilt part
1 Attach the flat part to the access point using two M6 screws.
2 Using the 1-axis tilt bracket as a template, mark and drill four holes on a wall or on a
flat surface.
3 Attach the 1-axis tilt part to a wall or a flat surface using four M6 head-size screws.
4 Align the KT-147407-02 flat part inside the 1-axis tilt part, and attach the flat part to
the 1-axis tilt part using four M6 screws.
5 Tilt the access point to a desired angle and tighten the four M6 screws to a torque of
45 in-lbs.
The tilt bracket can be adjusted from +15 degrees to -15 degrees of tilt.
Option 2: Install the Access Point to a Flat Surface Using the KT-147407-02
Flat Part, 1-axis tilt-Part, and KT-150173-01 Extension Arm
The KT-150173-01 extension arm is used in combination with the KT-147407-02 flat and 1-
axis tilt parts. The KT-150173-01 extension arm can also be used by itself on the access
point.
Figure 3 KT-150173-01 Extension arm
1 Attach the KT-147407-02 flat part to the access point using two M6 screws.
2 Place the KT-147407-02 flat part inside the 1-axis tilt part, and attach it using four M6
screws.
3 Using the KT-150173-01 extension arm as a template, mark and drill four hole centers
on a flat surface.
The holes must be within the semi-circular cuts of the extension arm.
4 Attach one end of the KT-150173-01 extension arm to the 1-axis tilt part using two hex-
head M12 stainless-steel screws and two hex-head M12 stainless-steel nuts through the
two large circular holes on the KT-150173-01 extension arm.
5 Attach the KT-150173-01 extension arm to a flat surface using four M6 hex-head screws
and screw-in anchors, if the extension arm is being mounted on a wood surface. If you
are mounting the extension arm on a concrete surface, use concrete anchors.
The M6 hex-head screws and screw-in anchors must be provided by the installer.
Option 3: Install the Access Point to a Flat Surface Using the MBO-ART02
Articulating Mounting Bracket
1 Using the short end of the MBO-ART02 articulating mounting bracket as a template,
mark and drill four holes on the wall.
Figure 4 MBO-ART02 bracket template for attachment holes
2 Attach the large end of the MBO-ART02 articulating mounting bracket to the access
point using two M6 hex-head screws.
3 Attach the short end of the MBO-ART02 articulating mounting bracket to the wall
using four M6 hex-head screws.
For installation instructions on how to use the WS-MBV-VMM (#32216) vehicle mount
bracket on a flat surface, refer to the ExtremeWireless Access Points AP460i/e Installation
Guide in the Extreme Networks Documentation Support site.
Install the Access Point to a Pole
The access point can be mounted on a pole with or without tilt.
Option 1: Install the Access Point to a Pole Using the KT-147407-02 Pole
Part
1 Attach the KT-147407-02 pole part to the access point using four M6 screws in the
circular slots.
2 Insert 0.5 in. wide stainless-steel cable clamps through the long slots on the pole
bracket.
3 Position the cable clamps on the pole part around a pole, and attach the access point
to the pole.
4 Insert the ends of the cable clamp around the pole and tighten it to a torque of 11 in-
lbs.
Note: The flat part and the 1-axis tilt part can be used
interchangeably to attach to the access point.
Option 2: Install the Access Point to a Pole Using KT-147407-02 Bracket
Parts and KT-150173-01 Extension Arm
1 Attach the KT-147407-02 1-axis tilt part to the access point using two M6 screws.
2 Align the KT-147407-02 flat part inside the 1-axis tilt bracket, and attach it using four
M6 screws.
3 Tilt the access point to a desired angle and tighten the four M6 screws to a torque of
45 in-lbs.
4 Attach one end of the KT-150173-01 extension arm to the 1-axis tilt part using two hex-
head M12 stainless-steel screws and two hex-head M12 stainless-steel nuts through the
two large circular holes on the KT-150173-01 extension arm.
5 Attach the KT-147407-02 pole part to the KT-150173-01 extension arm using two M12
screws and two M12 hex nuts.
6 Insert 0.5 in. wide stainless-steel cable clamps through the long slots of the pole part.
7 Position the cable clamps around a pole, and attach the access point to the pole.
8 Insert the ends of the cable clamp around the pole and tighten it to a torque of 11 in-
lbs.
For installation instructions on how to use all the parts of KT-147407-02 bracket, the MBO-
ART02 bracket on a WS-MBO-POLE01 bracket, refer to the ExtremeWireless Access
Points AP460i/e Installation Guide in the Extreme Networks Documentation Support site.
Professional Installation Instruction
Installation personnel
This product is designed for specific application and needs to be installed by a qualified
personnel who has RF and related rule knowledge. The general user shall not attempt to
install or change the setting.
External antenna
Use only approved antennas. The non-approved antennas may produce unwanted
spurious or excessive RF transmitting power which may lead to the violation of FCC/IC
limit and is prohibited.
Installation procedure
Refer to user’s manual for installation details.
Instructions d'installation professionnelle
Installation
Ce produit est destine a un usage specifique et doit etre installe par un personnel qualifie
maitrisant les radiofrequences et les regles s'y rapportant. L'installation et les reglages ne
doivent pas etre modifies par l'utilisateur final.
Antenn externe
Utiliser uniiquement les antennes approuvees par le fabricant. L'utilisation d'autres
antennes peut conduire a un niveau de rayonnement essentiel ou non essentiel
depassant les niveaux limites definis par FCC/IC, ce qui est interdit.
Procedure d'installation
Consulter le manuel d'utilisation.
GE and Console Connections
The access points have two GE (Ethernet) ports and a Console port. During
administration and maintenance through the Console port, the access points must still
have a power connection through an Ethernet PoE cable.
Antenna Configurations for External Antenna Model
Figure 5 AP460e external antenna connectors
Antenna socket radio mapping information
Radio 1 (R1) - antennas 5 and 6
Radio 2 (R2) - antennas 1, 2, 3, and 4
Radio 3 (R3) - antennas 7 and 8
Warning: Carefully select the installation position and make sure that the final
output power does not exceed the limit set forth in relevant rules. The violation
of the rule could lead to serious federal penalty.
Warning: Avertissement: Choisir avec soin la position d'installation et
s'assurer que la puissance de sortie ne depasse pas les limites en vigueur. La
violation de cette regle peut conduire a de serieuses penalites federales.

Summary of content (2 pages)