Installation guide
Integrated Antenna Model Suspended Ceiling T-Bar Mount Instructions
Altitude™ 4532 Series Access Point Installation Guide
15
Integrated Antenna Model Suspended Ceiling
T-Bar Mount Instructions
Ceiling mount requires holding the Altitude 4532 Access Point up against a T-bar of a
suspended ceiling grid and twisting the case onto the T-bar.
Suspended Ceiling Mount Procedure
1 If required, install and attach a security cable to the unit’s lock port.
2 Plug the Ethernet cable into the unit and to a controller with an 802.3af compatible
power source.
3 Align the bottom of the T-bar with the back of the case.
4 Orient the case by its length, and the length of the T-bar.
5 Rotate the case 45 degrees clockwise, or about 10 o’clock.
6 Push the back of the case onto the bottom of the T-bar.
7 Rotate the case 45 degrees counter-clockwise. The clips click as they fasten to the T-bar.
8 Verify the unit has power by observing the LEDs.