Specifications

Application States
Summit WM Series WLAN Switch and Altitude Access Point Software Version 4.1 Technical Reference Guide
63
Error LED
Failed to identify FDD. Possibly
due to removal of FDD card.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 1
Re-insert card. If card
present, contact Technical
Support to arrange
replacement.
Failed to initialize NPE card.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 2
Re-insert card. If card
present, contact Technical
Support to arrange
replacement.
Critical threshold reached (95C
for NPE). System will reboot.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 3
Check speed/state for fans.
Check for proper airflow
access. If problem persists,
contact Technical Support,
Full fan assembly failure (both
trays). System will reboot.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 4
Re-insert fan tray. If card
present, contact Technical
Support to arrange
replacement.
Application initialization failure.
Startup manager failed to
initialize all of system’s
components. system will reboot.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 5
If problem persists, contact
Technical Support.
Lost connectivity with FE.
Possible failure of NPE card.
System will reboot.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 6
Investigate failure condition
in
/var/controller/log/
logs/ixcapture.log
If problem persists, contact
Technical Support.
MCE failure. Backup sectors
exhausted.
l Activity LED = Enabled
l Warning LED = Enabled
l Error LED = Enabled
lSSD= 7
Contact Technical Support to
arrange replacement.
Table 8: WM200/2000 Application States (Continued)
Condition Log Level Comment Action