Specifications
Summit WM series switch WM200/2000 Diagnostics
Summit WM Series WLAN Switch and Altitude Access Point Software Version 4.1 Technical Reference Guide
62
Forwarding Engine initialization
complete. Application initializing.
• Activity LED = Enabled
• SSD= 1
Major FE initialization complete No Action Required
Application initialization
complete. System active.
• Activity LED = Enabled
• SSD= A
Major Complete set of application
components have restarted.
System is now ready to enter
active state.
No Action Required
System halted. Administrator
requested halting of system.
• Activity LED = Enabled
• SSD= H
Major This SSD code indicates that
the administrator has requested
the halting of system's
operations. The system is in
halted state.
Reset system power to
restore operational state.
Warning LED
High Temperature reached
• Activity LED = Enabled
• Warning LED = Enabled
• Alarm = MAJOR
• SSD= 1
Major
(set)
Info
(reset)
Temperature in one of the
system's sensors has reached
high threshold notification of
occurrence.
Check speed/state indicators
for FANs. Check for proper
airflow access. If problem
persists, contact Technical
Support.
Fan unit failure. Rotation counter
indicates Zero speed for one of
the lateral trays. May be result of
tray removal.
• Activity LED = Enabled
• Warning LED = Enabled
• Alarm = MINOR
• SSD= 2
Minor Rotation counter for Fan
indicates Zero for one of the
lateral trays. May also be the
result of fan tray removal (hot
swap) System is at risk of over-
heating.
Re-insert fan tray. If card
present, contact Technical
Support.
Power supply failure. Failed to
detect one of the power supplies,
may have been removed.
• Activity LED = Enabled
• Warning LED = Enabled
• Alarm = MAJOR
• SSD= 3
Major Failure Detected for one of the
power supplies
Re-insert power block. If
block present, contact
Technical Support.
FDD low sector count (40 backup
sectors remaining).
• Activity LED = Enabled
• Warning LED = Enabled
• Alarm = MAJOR
• SSD= 4
Major Media Storage utilization has
only 40 free blocks available
leveling. Card is getting close
to max sector re-use
Contact Technical Support to
arrange replacement.
FDD extremely low sector count
(20 backup sectors remaining).
• Activity LED = Enabled
• Warning LED = Enabled
• SSD= 5
Major Media Storage utilization has
reached critical level of free
sector utilization. No more
free-sectors available. -
Recommend replacement.
Contact Technical Support to
arrange replacement.
Table 8: WM200/2000 Application States (Continued)
Condition Log Level Comment Action