Specifications
MU_SESMGR_ID (66)
Summit WM Series WLAN Switch and Altitude Access Point Software Version 4.1 Technical Reference Guide
147
MU_SESMGR_ID (66)
37 Mobility manager startup. Component state None
38 RU Session Manager startup. Component state None
Info
65 Access point registration and
authentication succeeded. (%S.)
Access Controller registration
state
None
66 Access point registration and/or
authentication failed. (%S.)
Access Controller registration
failed. AP unsuccessful in
establishing credential exchange
with controller. AP will retry.
If problem persists Contact
Technical Support for
investigation.
67 Access point session poll
disconnect AP session timed
out. (%S.)
AP disconnected from active
controller. May no longer be
available for RF coverage.
Determine if outage was caused
by configuration change (Delete/
Pending/Release). Determine if
outage was caused by network
path interruption. If interruption
was caused by functional issue
with AP or controller please
contact Technical Support to
investigate.
68 Access controller tunnel
registration failed (%s).
Possible Feature Impact. Some
possible user impact as tunnel
change purges sessions
associated with peer. Users if
connected will need to re-
authenticate and renegotiate
topology profile.
Determine if outage was caused
by configuration change to
Mobility feature (add/Remove of
controllers from Mobility
Domain). Determine if outage
was caused by network path
interruption. If interruption was
caused by failure of Mobility
controller, please review log file
to determine appropriate root
cause and corresponding action.
69 Access point software version
validation failed. (%s)
AP was determined to not be
running an adequate firmware
version for operation with
controller. May be result of
administration specification of
firmware upgrade request.
Validate version incompatibility
of AP. Verify that correct
upgrade image is available.
Upgrade will take place
automatically.
70 %s transmission failed. Interprocess communication
failure between AP and
controller.
If problem persists Contact
Technical Support for
investigation.
Table 34: MU_SESMGR_ID (66) logs and events
Log
ID
Log Message Comment Action
Minor
33 Maximum number of home
sessions has been reached. No
more home users will be
permitted.
Reached maximum user
capacity for system. Need to
deploy additional controllers to
take on excessive capacity.
Contact Sales support to discuss
expanding deployment.
Table 33: RU_SESMGR_ID (65) logs and events (Continued)
Log
ID
Log Message Comment Action