Specifications
Logs and Events
Summit WM Series WLAN Switch and Altitude Access Point Software Version 4.1 Technical Reference Guide
118
67 Error trying to close all sockets.
However, they will time out on
their own.
No negative impact to system.
However indicates possible issue
with resource de-allocation.
If problem persists, contact
Technical Support to investigate.
68 Cannot connect to Radius
Client. Will keep trying until
connection is successful.
Inter-communications issue.
Component re-attempts should
restore proper link. However, if
un-resolved will not allow
authentication to proceed and
therefore blocking any users
from gaining proper access to
network.
If problem persists, contact
Technical Support to investigate.
69 Cannot connect to EAP. Will
keep trying until connection is
successful.
Inter-communications issue.
Component re-attempts should
restore proper link. However, if
un-resolved will not allow EAP
(WPA) authentication to proceed
and therefore blocking any users
in AAA assigned WM-ADs.
If problem persists, contact
Technical Support to investigate.
70 Internal communication failure -
cannot make internal data
connection. Will keep trying
until connection is successful.
Internal interprocess
communication issue.
If problem persists, contact
Technical Support to investigate.
71 Error on socket select. The
socket must have already been
closed.This should not impact
whether an authentication
request succeeds or fails for a
session.
Internal interprocess
communication issue.
If problem persists, contact
Technical Support to investigate.
72 Error accepting new socket. Will
not be able to receive login
information from Apache server.
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to investigate.
73 Error trying to send a message
to Radius Client. Captive portal
authentication request will fail.
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to investigate.
74 Send
SECMGR_MU_AUTHENTICATED
_NOTIFY message failed for
token%d
Internal interprocess
communication issue. Users
authenticated via internal
captive portal may not reach
authenticated state even with
proper credentials. Component
may need to be restarted.
If problem persists, contact
Technical Support to investigate.
Table 18: SECURITY_MANAGER (4) logs and events (Continued)
Log
ID
Log Message Comment Action