A power cord is not supplied with the controller. Use only a correctly rated power cord certified (as
appropriate) for the country of operation
.
Power Protection
● If possible, use a circuit dedicated to data processing equipment. Commercial electrical contractors
are familiar with wiring for data processing equipment and can help with the load balancing of these
circuits.
● Install surge protection. Be sure to use a surge protection device between the electricity source and
the Summit WM3700 wireless LAN controller.
● Install an Uninterruptible Power Supply (UPS). A UPS provides continuous power during a power
outage. Some UPS devices have integral surge protection. UPS equipment requires periodic
maintenance to ensure reliability. A UPS of the proper capacity for the data processing equipment
must be purchased.
Width
440mm (17.32 in)
Height
44.45mm (1.75 in)
Depth
390.8mm (15.38 in)
Weight
6.12 Kg (13.5 lbs)
Operating Temperature
0°C - 40°C
Operating Humidity
5% - 85% RH, non-condensing
Operating Altitude
3 km (10000 ft)