Specifications
72 ExtremeWare 7.3.1b3 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
You can safely ignore these messages (PD2-208576301).
Output of the show log Command
The most common reason for transceiver diagnostics failure is heat. Thus the show log output displays
the TRXDIAG tag in the temperature log message (PD2-147462529).
The unconfigure switch all Command Clears the Default VLAN from s0
After you reset the switch to the factory defaults using the unconfigure switch all command, s0
does not contain the default VLAN. To add the default VLAN to s0, delete then add all ports in the
default VLAN (PD2-143709201).
Health Check Error Messages
Error messages from the system health check display the incorrect location (PD2-110132842).
Summit48i Redundant PHY
When the primary port of a redundant pair is disabled and the link removed, the LED for that port
continues to flash indicating it has a link and is disabled (9239).
Summit48i Single Fiber Signal Loss
The Summit48i is currently not able to detect a single fiber strand signal loss due to the hardware based
Auto Negotiation parameters (10995).
SNMP Results for Power Sources
The inputPower MIB is unable to differentiate between 110 VAC and 220 VAC input on the Summit
series switches when accessing this MIB attribute through SNMP (10870).
Summit48si MIB value for Input Power Voltage
On the Summit48si, the extremeInputPowerVoltage attribute in extremeSytemCommonInfo is shown as
“0” and the extremePowerSupplyInputVoltage in the extremePowerSupplyTable is shown as
“unknown.” These values cannot be obtained from the switch (1-841J1).
Command Line Interface (CLI)
Mirroring Cannot be Disabled
Mirroring cannot be disabled until all mirroring ports are deleted (PD2-244886705).
Console Does Not Wait for User Input
The console is not waiting for a response after issuing the prompt Continue? (yes or no) <<<.
When you press the ENTER key, the key strokes being sent are CR+LF. With a console connection, the
switch interprets this as though you pressed the ENTER key twice. This problem does not occur if you
are using a Management port connection.