Specifications
62 ExtremeWare 7.3.1b3 Release Notes
Clarifications, Known Behaviors, and Resolved Issues
Autonegotiation Between Fiber Optic Ports is not Possible
A port from a Fast Ethernet switch, when connected to any gigabit port, does not recognize the speed
mismatch. The port appears active even though the gigabit port is inactive (PD3-2073971).
show log Command Memory Error
When running debug-trace for AgentX-APi, the show log command output shows an AP failure due to
the switch being “out of memory,” even though it is not (PD3-2617791).
unconfigure switch all Command Should Not Restore the Downloaded Configuration
When downloading a new configuration to the switch, you are prompted with the following message:
New configuration file has been successfully downloaded to memory.
To make the new configuration effective, the system needs to reboot.
Would you like to reboot the system? (Y/N)
If you choose N, the new configuration should not take effect. Issuing the unconfigure switch all
command should restore the switch to the factory defaults. However, instead of restoring the factory
defaults, the switch again applies the previously downloaded configuration (PD3-2536041).
WLANSYST Output of the show log Command is Not Correct
The output for the show log command always shows the WLANSYST message twice. This does not
impact switch performance (PD3-2450049).
System Related – All Systems
The NVRAM Dirty Bit Being Set from the PoE Code
The NVRAM dirty bit is being set from the PoE code that saves the connection history (PD3-2963230).
PoE Firmware image Download is not Available in Base Image
The PoE firmware image has been removed from the base image. The current base image will give an
error message if it detects a PoE module on an Alpine switch. For the PoE feature to work correctly, use
the unified (.xtr) image, not the base (.Bxtr) image (PD3-2011501).
Autonegotiation Setting Not Preserved on Added and Deleted Loopback Ports
If you add a 10/100 port as a loopback port and delete it, autonegotiation is set to off (PD2-192574401).
Configure Slot for PoE Before Configuring or Downloading PoE Configuration
You must configure a slot for a PoE module before downloading a PoE configuration. Downloading a
PoE configuration to a switch without a PoE module configured generates an error message similar to
the following:
Error: slot 8 is not PoE capable!
To avoid this, configure the slot for a PoE module before saving the configuration (PD2-209577118).