Installation guide

372 Extreme Networks Consolidated "e" and "i" Series Hardware Installation Guide
Installing GBICs and Mini-GBICs
Installing or Replacing a GBIC
You can add and remove GBICs from a Extreme Networks switch without powering off the system.
Figure 180 shows the three types of GBICs.
Figure 180: GBIC types
CAUTION
Use only Extreme-approved optic devices within Extreme switches. Optical modules provided by
Extreme Networks are compliant for use with Extreme systems.
To insert a GBIC:
1 Holding the GBIC by its sides, insert the GBIC into the slot on the I/O module or the switch.
2 Slide the GBIC into the slot until you hear an audible click, indicating the GBIC is securely seated. If
the GBIC has a handle, push down on the handle to secure the GBIC.
NOTE
Remove the SC fiber-optic or the RJ-45 connector from the GBIC before removing the GBIC from the
I/O module or the switch.
To remove a GBIC similar to the one labeledModule A in Figure 180, rotate the front handle up and
pull the GBIC out of the slot.
To remove a GBIC similar to one labeled “Module B” or “Module C” in Figure 180, squeeze the side
tabs to release the GBIC, and pull the GBIC out of the slot.
EW_GBIC
Module A Module B Module C
Handle
Tab
Tab