Installation guide

230 Extreme Networks Consolidated "e" and "i" Series Hardware Installation Guide
BlackDiamond 6800 Series Switch Overview
Figure 129: 110 VAC power supplies in a BlackDiamond 6808 or a BlackDiamond 6804 switch
Table 47 on page 230 describes the LED activity on the 110 VAC power supply
DC Power Supplies
The DC inputs are located on the front of the power supply. Each set of power terminals on the DC
power supply consists of two 6-mm, metric-threaded, nickel-plated, brass studs that are centered 0.625
inch (15.86 mm) apart.
The earth ground studs extend 0.52 inch (13.2 mm) above the power supply faceplate; the set of positive
(+) and negative (–) studs extend 0.9 inch (22.9 mm) above the faceplate. The nickel plating on the studs
enhances conductivity and resists corrosion.
The input terminals are isolated from the ground terminals. The BlackDiamond DC power supplies
operate with DC input that can range from -42 to -70 V. Each DC power supply requires a dedicated
60 A service.
The DC power supply ships with the input lugs attached to the power supply, and the power supplies
slide in from the front of the chassis, as illustrated in Figure 130.
Table 47: 110 VAC power supply LED activity
LED Color Indicates
AC In Green
Amber
Off
Powered using both inputs
Powered using only one input, or input voltage is less than 100 V
No input power
DC Out Green
Amber
Off
All DC outputs are operational
One or more DC outputs failed
No power
AC IN
BD_026
DC OUT
50020
POWER
DC OUT
AC IN
50020
POWER