Installation guide

Altitude 300-2 Getting Started Guide 25
Plenum certified
Temperature
Operating Temperature 0°C to 40°C (32 F to 104 F)
Transportation Temperature:-40°C to 70°C (-40 F to 158 F)
Operating Humidity:10% to 95% relative humidity, non- condensing
Operational Shock: 30 m/s2 (3g), 11ms
Packaged Shock: 180 m/s2 (10g), 6ms, 600 shocks
Operational Vibration: 3-500MHz @ 1.5g rms
Packaged Vibration: 5-20 Hz @ 1.0 ASD w/-3dB/oct. from 20-200 Hz
Operational & Transportation Standards
EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
ASTM D5276 Drop Packaged
ASTM D3580 Random Vibration Unpackaged 1.5G
Standards
IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX
IEEE 802.11a/b/g
IEEE 802.3af
Wi-Fi member
NOTE
802.11abg should be used only in countries that permit 802.11abg or 802.11bg operation.
Sensitivity
Table 3: 802.11a Radio
Modulation/Rates Sensitivity (dBm)
BPSK (6 Mbps) -88
BPSK (9 Mbps) -87
QPSK (12 Mbps) -86
QPSK (18 Mbps) -84
16 QAM (24 Mbps) -81
16 QAM (36 Mbps) -77
64 QAM (48 Mbps) -73
64QAM (54 Mbps) -69
Table 4: 802.11b/g Radio
Modulation/Rates Radio Type Sensitivity (dBm)
DSSS-DBPSK (1Mbps) b -91