Operating Conditions
Temperature Range
• 0° C to 45° C (32° F to 113° F)
• Humidity: 10% to 95% relative humidity, non-condensing
• Altitude: 0 to 3,000 meters (9,850 feet)
• Shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks
• Random vibration: 3 to 500 Hz
• at 1.5 G rms
Storage & Transportation
Conditions (Packaged)
• Transportation Temperature: -40° C to 70° C (-40° F to 158° F)
• Storage and Transportation Humidity: 10% to 95% RH,
non-condensing
• Packaged Shock (Half Sine): 180 m/s2 (18 G), 6ms, 600
shocks
• Packaged Sine Vibration: 5-62 Hz @ Velocity 5mm/s, 62-
500 Hz @ 0.2G
• Packaged Random Vibration: 5-20 Hz @ 1.0 ASD w/-3dB/
oct. from 20-200 Hz
• 14 drops min on sides & corners @ 42”
(<15kg box)
EMI/EMC Standards
• FCC CFR 47 part 15 Class A (USA)
• ICES-003 Class A (Canada)
• 2004/108/EC EMC Directive
• EN 55022:2010 Class A (Emissions
for ITE Equipment)
• EN 55024:2010 Class A includes EN 61000-4-2, 3, 4, 5, 6, 11
• EN 55011 :2009+A1:2010 (Emissions for Industrial, Scientific
& Medical Radio Frequency Equipment)
• EN 61000-3-2: 2006+A2 2009 (Harmonics)
• EN 61000-3-3:2008 (Flicker)
• EN 61000-6-4: 2007+A1: 2011 (General Emissions for
Industrial, Scientific & Medical)
• EN 61000-6-2:2005 (General Immunity for Industrial,
Scientific & Medical)
• EN 50121-4:2006 (Emission and immunity of the signaling
and telecommunications apparatus)
International EMC Standards
• CISPR 22:2008 Class A (International Emissions for ITE
Equipment)
• CISPR 24:2010 Class A (International Immunity for ITE
Equipment)
• IEC 61000-4-2:2008/EN 61000-4-2:2009 (Electrostatic
Discharge, 8kV Contact, 15kV Air, Criteria A)
• IEC 61000-4-3:2010/EN 61000-4-3:2006+A12008 +A2:2010
• Radiated Immunity 20V/m, 80-960MHz, Criteria A
• Radiated Immunity 10V/m, 960-2100MHz, Criteria A
• Radiated Immunity 5V/m, 2100-2700MHz, Criteria A
• IEC 61000-4-4:2011/EN 61000-4-4: 2004+A1: 2010 Transient
Burst
• Power AC, ± 2.0kV, Criteria A
• Power DC, ± 2.0kV CM, 1kV DM, Criteria A
• I/O Cables, ± 2.0kV for all I/O longer than 3m
• IEC 61000-4-5:2005/EN 61000-4-5:2006 Surge, Test to
2/4kV, Level 3
• AC Power, 1/2kV , Criteria A
• DC Power 1kV DM, 2kV CM, Criteria A
• I/O 1kV L-G, Criteria A
• IEC 61000-4-6:2008/EN 61000-4-6:2009 Conducted
Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A
• IEC 61000-4-8:2009/EN 61000-4-8:2010 Magnetic
Immunity, Not applicable to Extreme’s equipment
• IEC 61000-4-11:2004/EN 61000-4-11:2004 Power Dips &
Interruptions, >30%, 25 periods, Criteria C
• VCCI Class A (Japan Emissions)
• ACMA (C-Tick) (Australia Emissions)
• CCC Mark
• KCC Mark, EMC Approval (Korea)
Telecom Standards
• ETSI EN 300 386: V1.5.1 (2010-10) EMC Telecommunications
• ETSI EN 300 019 (Environmental for Telecommunications)
• MEF 9 compliant
• MEF 14 compliant
IEEE 802.3 Media Access Standards
• IEEE 802.3ab 1000BASE-T
• IEEE 802.3z 1000BASE-X
• IEEE 802.3at PoE Plus