Datasheet
© 2010 Extreme Networks, Inc. All rights reser ved. Summit X350 Series—Page 7
Extreme Networks Data Sheet
Technical Specifications
QoS and VLAN Services
Quality of Service and Policies
• Quality of Service and Policies
• IEEE 802.1D – 1998 (802.1p) Packet Priority
• RFC 2474 DiffServ Precedence, including
8 queues/port
• RFC 2598 DiffServ Expedited Forwarding (EF)
• RFC 2597 DiffServ Assured Forwarding (AF)
• RFC 2475 DiffServ Core and Edge
Router Functions
Summit X350-24t
General Specifications
Performance
• 88 Gbps switch fabric bandwidth
• 65.5 Mpps frame forwarding rate
• 9,216 Byte maximum packet size
(Jumbo Frame)
• 13 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per switch
Forwarding Tables
• Layer 2/MAC Addresses: 8K
Rate Limiting
• Ingress bandwidth policing/rate limiting
per flow
• Egress bandwidth rate shaping per
egress queue and per port
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED including power status
• System Status LEDs: management, fan
and power
Ports
• 24 ports 10/100/1000BASE-T with
auto-speed and auto-polarity
• 4 ports 1000BASE-X SFP (shared PHY with 4
10/100/1000BASE-T ports)
• 1 port Serial (control port)
• 1 10/100BASE-TX out-of-band management Port
• Per port status LED including power status
• Slot for XGM2 10 Gigabit Option Module
External Power Supply Support
• EPS-500
VLAN Services: VLANs, vMANs
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1v: VLAN classification by Protocol
and Port
• Port-based VLANs
• Protocol-based VLANs
• MAC-based VLANs
• Multiple STP domains per VLAN
• Upstream Forwarding Only/Disable Flooding
• RFC 5517 Private VLANs
Physical Specifications
Dimensions
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 15.3 Inches/38.7 Cm
• Weight: 13.75 Lbs / 6.24 Kg
Operating Specifications
Temperature
• Operating Temperature Range:
0° C to 40° C (32° F to 104° F)
• Operating Humidity: 10% to 93% relative
humidity, non-condensing
• Operational Shock (Half Sine):
30 m/s2 (3g), 11ms, 60 Shocks
• Operational Random Vibration:
3 – 500 MHz @ 1.5g rms
Storage & Transportation Conditions (Packaged)
• Transportation Temperature:
-40° C to 70° C (- 40° F to 158° F)
• Storage and Transportation Humidity:
10% to 95% RH, non-condensing
• Packaged Shock (Half Sine):
180 m/s2 (18g), 6ms, 600 shocks
• Packaged Sine Vibration: 5 – 62 Hz @ Velocity
5mm/s, 62 – 500 Hz @ 0.2 G
• Packaged Random Vibration: 5 – 20 Hz @ 1.0
ASD w/-3dB/oct. from 20 – 200 Hz
• 14 drops min on sides & corners @ 42”
(<15kg box)
• VLAN Translation
• IEEE 802.1ad Provider Bridge Network, virtual
MANs (vMANs)
• vMAN Ethertype Translation/Secondary
vMAN Ethertype
• Multicast Support for PVLAN
• Multicast Support for VLAN Aggregation
Power & Acoustic Sound
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100 – 240V,
50/60Hz, 1.0A
• Nominal Input Current: 0.75A @ 115V~ (lowline)
0.4A @ 230V~ (highline)
• Maximum In-Rush Current: 30A @115V;
60A@230V/60 Hz, Max Load
• Efficiency: 80% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Nominal Frequency Range: 50 – 60 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 75W (256 BTU/hr)
• Nominal Maximum Power Consumption:
75W (256 BTU/hr)
• Sound Power in accordance with
EN 300 753 (10-1997)
• Sound Power: 48.7 dBA
• Declared Sound Power: 6.4 belsA per
ISO 7779 & ISO 9296
• Bystander Sound Pressure in accordance with
NEBS GR-63 Issue 2
• Bystander Sound Pressure: 38.9 dBA