User manual
31
alaRMs
Display eXplanaTion soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression 
sensor.
The alarm can be reset by pressing key 1 for 3 seconds only 
if the fumes motor has stopped and if 15 minutes have 
passed from when the alarm was displayed.
aspiRaTion faulT 
Fumes motor fault Contact after-sales centre
fuMes pRoBe 
Fumes probe failure. Contact after-sales centre
HoT fuMes 
High ue gas temperature
Verify pellet feed (see “Pellet feed regulation”). If the problem 
cannot be solved, contact an authorised technician.
no floW alaRM 
all clean cHeck up
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Ensure that the fumes pipe, primary air duct and combustion 
chamber are clean.
no 
iGniTion 
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the feed-box.
Adjust pellet ow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
no iGniTion 
Black ouT
No current during the ignition phase.
Take the stove to OFF conditions using key 1 and repeat the 
procedure described in the "Ignition" chapter.
no pelleTs 
The pellet feed-box is empty.
No pellet feed.
The motor reducer does not feed pellets.
Check for the presence of pellets in the feed-box.
Adjust pellet ow (see “Pellet feed adjustment”).
DepR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion 
chamber.
DeBiMeTeR 
faulT 
Faulty ow sensor.
Sensor disconnected
Contact after-sales centre
H20 
oveRTeMpeRaTuRe 
The water in the stove has exceeded 95°C. 
Possible air in the system.
Insucient circulation.
No or inadequate safety zone.
Possible circulator anomaly.
Contact after-sales centre
MiniMuM pRessuRe 
alaRM 
The system pressure read by the pressure 
switch is too low. 
Possible presence of air in the system.
Possible lack of water or leaks due to 
anomalies in some system component.
Contact after-sales centre
H2o 
pRoBe alaRM
H2O probe failure
MaX H2o 
pRessuRe alaRM
The pressure of the water has exceeded 
the max threshold 
Check that the expansion vessels are not damaged or 
under-dimensioned
Check that the cold system is loaded at the correct pressure
 | enGlisH