MAKE SURE THAT THE ASH IS COMPLETELY COLD BEFORE EMPTYING IT INTO A SUITABLE CONTAINER. * THE
“CHIMNEY SWEEP” BIN IS AN ACCESSORY AVAILABLE FROM THE COMPANY.
ROUTINE MAINTENANCE
In order to guarantee proper functioning and safety of the device, the operations indicated below must be performed every
season or more often when necessary.
DOOR, ASH DRAWER AND BURN POT GASKETS
The gaskets guarantee the tightness of the stove and its consequent good functioning.
These must be checked regularly: if they should be worn or damaged they must be replaced immediately.
These operations must be carried out by a qualied technician.
CONNECTION TO THE FLUE
Suck and clean the pipe that leads to the ue yearly or anytime that it is necessary. If there are horizontal tracts the residues must
be removed before they can obstruct ue passage.
NONCLEANING JEOPARDISES SAFETY.
IF THE POWER SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY THE AFTERSALES SERVICE OR BY A
SIMILARLY QUALIFIED PERSON, SO AS TO AVOID AL RISKS.
FOR CORRECT FUNCTIONING, THE STOVE MUST UNDERGO ROUTINE MAINTENANCE BY A QUALIFIED TECHNICIAN,
AT LEAST ONCE A YEAR.
CLEANING UNDER USER'S RESPONSIBILITY
Some images could be oset from the original model.
| ENGLISH
MONTHLY
Cleaning the deector:
The smoke deector located under the cleaning springs of the heat exchanger must be removed every month. Move it as
follows: remove part A of the door upper deector xed with 3 screws, remove part B of the door upper deector xed with
2 screws and remove the smoke central deector as if it were a drawer.
A
B