User manual
26
 | ENGLISH
ADJUSTING LANGUAGE
• see chapter: rst ignition settings
DISPLAY
This menu allows to regulate the brightness of the display. The possible settings range from OFF - 10 to 31.
Activating OFF, the back light of the display will go o after a preset delay. 
The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine.
CONTROLS PROCEDURE
  Press key 6 and SET POWER will appear.
  Press key 2 several times until USER is displayed. 
  Press key 2 until DISPLAY.
  Press keys 4-5 to select the brightness
  Press key 6 to conrm and key 1 to return to the previous menus up to 
the initial status.
OFF
OFF
RESET
Allows to reset all values modiable by the user back to the default values. The data are:
  CONTROLS PROCEDURE
 
  Press key 6 and SET POWER will appear.
  Press key 2 several times until USER IS DISPLAYED. 
  Press key 2 until RESET.
  Press keys 4-5 to select ON and press key 6.
  "DONE" will appear on the display to conrm the command
  SET H2O = 75°C
  SET POWER = 5 
  ENABLE CHRONO = OFF
  START PRG1=OFF
  STOP PRG1 = OFF
  MONDAY PRG1 = OFF
  .......all chrono parameters OFF 
  PELLET = 00%
  STAND BY = OFF 
OTHER FUNCTIONS
AIR DISCHARGE
This function allows to bleed any air in the stove. Activates the function:
The pump indicator lights on the display will go on (the pumps will be powered for 15 minutes and 30 seconds and will then stop for 30 
seconds; cut the power to interrupt)
CONTROLS PROCEDURE
  Press key 1 and 4 simultaneously.
  The password will be required.
  Enter the code "77" via key 4
  Conrm using key 6.