User manual
OFF
16
CONTROL BOARD
ON/OFF
BUTTON
DISPLAY OF VARIOUS
TEXT MESSAGES
TO ACCESS
THE MENU
TEMPERATURE
SETTING
OPERATION POWER
ADJUSTMENT
| ENGLISH
DISPLAY ICONS KEY
Indicates the receipt of the radio signal
On = during radio communication
O = no radio communication
Flashing = excluded serial port
Indicates the stove modulation
On = the stove is working at the set power
Flashing = the power at which the stove is working is dierent to
the power set, the stove is modulating (for various reasons)
Indicates the presence of an alarm.
On: indicates the presence of an alarm
O: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
It indicates weekly programming functioning
Indicator on = Weekly programming active
Indicator o = Weekly programming not active
Indicates the water temperature status
O = the T° read by the probe is over the set temperature set
On = the T° read by the probe is below the set temperature set
Indicates the contact of the external additional thermostat
Contact closed: the contact of the external additional thermostat
is closed.
Contact open: the contact of the external additional thermostat is
open.
Flashing with closed contact: the contact of the external additional
thermostat is closed and the STBY function is activated
Flashing with open contact: the contact of the external additional
thermostat is open and the STBY function is activated
It indicates functioning of the fumes motor.
O = ue gas motor deactivated
On = ue gas motor active
Flashing = breakdown (contact technical after-sales service)
It indicates the summer / winter function (with an additional board)
O: Activates the winter function
On: Activates the summer function
Not used
It indicates the boiler request (with an additional board)
O: DHW satised, pump o
Flashing: the DHW request exists but the work conditions are not
satised, pump o
On: the DHW is in request mode and the work conditions are
satised, pump on
It indicates functioning of the pellet feed motor.
O = pellet feed motor deactivated
On = pellet feed motor active.
It indicates the heating request (with an additional board)
O: heating satised, pump o
Flashing: the heating request exists but the work conditions are not
satised, pump o
On: the heating is in request mode and the work conditions are
satised, pump on
It indicates pump functioning
O = pump deactivated
On = pump active
Flashing = the safety device is active (H2O temperature > 85°C)
It indicates the puer request (with an additional board)
O: puer satised, pump o
Flashing: the puer request exists but the work conditions are not
satised, pump o
On: the puer is in request mode and the work conditions are satis-
ed, pump on