CONNECTION TO EXTERNAL AIR INLETS
The appliance must be able to use the necessary air to guarantee regular functioning through external air inlet. The air inlets
must comply with the following requisites:
have a total free section of at least 80 cm².
must be protected by grates, metal net or suitable protections as long as they do not reduce the minimum section stated
in the previous point and positioned in order to avoid them being obstructed.
If the combustion agent air is withdrawn directly from outside through a pipe, a downward bend must be mounted outside
or a protection against the wind and no grates or similar must be positioned, (it is recommended that the air vent always
communicates directly with the installation room even if the air is withdrawn from outside through a pipe). The air ow can also
be obtained from an adjacent room, as long as the ow takes place freely through permanent openings communicating with
the outside.
The adjacent room, with respect to the installation room, must not be put in depression with respect to the external environment
by means of reverse draught caused by the presence of another used appliance or intake device in such room. The permanent
openings in the adjacent room must comply with the above-described requisites. The adjacent room cannot be set up as garage,
storage for combustion material or activity with danger of re.
INSULATION, FINISHINGS, COVERING AND SAFETY RECOMMENDATIONS
The coverings, independently from the materials from which they are made, must constitute a self-supporting construction
with respect to the heating block and not be in contact with it.
The cross members and nishings in wood or combustion materials must be positioned outside the hearth radiation area or
adequately insulated.
If coverings in combustion material or sensitive to heat exist in the space above the generator, an insulating and non combustible
protection diaphragm must be inserted.
Elements in combustible or inammable material like wooden furniture, curtains, etc. directly exposed to the hearth radiation,
must be positioned at a safe distance. The appliance installation must guarantee easy access for cleaning the appliance itself,
discharge gas pipe and ue.
CHIMNEY CAPS, DISTANCES AND POSITIONING
Roof inclination Distance between the ridge and the chimney Minimum chimney height (measured from outlet)
β A (m) H (m)
15°
< 1,85 0.50 m over the ridge
> 1,85 1.00 m from roof
30°
< 1,50 0.50 m over the ridge
> 1,50 1.30 m from roof
45°
< 1,30 0.50 m over the ridge
> 1,30 2.00 m from roof
60°
< 1,20 0.50 m over the ridge
> 1,20 2.60 m from roof
| ENGLISH
Open the tank lid and load the pellets using a scoop.
PELLETS AND FEEDING
The pellets used must comply with the features described by
the Standard:
Ö-norm M 7135
DIN plus 51731
UNI CEN/TS 14961
Extraame recommends the use of pellets with
use pellet having a 6 mm diameter.
THE USE OF BAD QUALITY PELLETS OR ANY OTHER MATERIAL CAN DAMAGE YOUR STOVE AND WILL MAKE THE
WARRANTY NULL AND VOID, RELEASING THE MANUFACTURER FROM ANY LIABILITY.