User manual

B
C
A
S
< 3 m
3 - 5 %
13
CHIMNEY OR INDIVIDUAL FLUE
The chimney or individual ue must respond to the following requisites:
seal the combustion products, be waterproof and adequately insulated in line with the use conditions;
be realised with materials which resist the normal mechanical stress, heat, action of the combustion products and any
condensate;
have mainly vertical progress with deviations from the axis not higher than 45°;
be adequately distanced from fuel or ammable materials through air space or opportune insulation;
have preferably circular internal section: the square or rectangular sections must have round corners with a radius not
lower than 20 mm;
have constant internal section, free and independent;
have rectangular section with max. ratio between the sides of 1.5.
It is recommended that the smoke pipe be equipped with a collection chamber for solid materials and any condensate situated
under the smoke channel inlet, so that it can be easily opened and inspected from airtight door.
REFERENCES INFLAMMABLE OBJECTS NONINFLAMMABLE OBJECTS
A 200 mm 100 mm
B 1,500 mm 750 mm
C 200 mm 100 mm
Minimum 80 cm
2
S= oor protection
Air inlets
Chimney cap
windproof
Flue
Inspection
Inspection
Flue
Inspection
| ENGLISH