LUCREZIA IDRO LCD USER MANUAL ENGLISH/INGLESE
We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. Extraflame S. p. A. Warnings................................................................................................................................................................................... 5 Safety........
Menu structure....................................................................................................................................................................22 Set power ..................................................................................................................................................................................................................................23 Set temperature............................................................................
| ENGLISH Warnings The instruction manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner or user or if transferred to another place. If it is damaged or lost,request another copy from the area technician. This product must be intended for the use it has been specifically made for.
| ENGLISH HYDRAULIC SYSTEM Certain concepts referring to the Italian UNI 10412-2 (2009) Standard are described in this chapter. As previously described, when installing, all national, regional, provincial and town council Standards in force provided by the country in which the appliance has been installed must be complied with.
| ENGLISH Component Distance Temperature safety sensors On the machine or not exceeding 30 cm Missing devices because not as per standard Not exceeding one metre, on the flow pipe The domestic heating appliances with automatic feeding must: be supplied with a fuel block thermostat or be supplied with a cooling circuit set-up by the appliance manufacturer. The cooling circuit must be activated by a heat safety valve such to guarantee that the limit temperature set by the Standard is not exceeded.
| ENGLISH smaller section than the inlet of the safety valve or the sum of the inlet sections in case of more valves heading a single pipe. The discharge piping of the safety valve must be realised in order not to prevent the regular functioning of the valves and not to cause damages to persons; the discharge must flow immediately near the safety valve and be accessible and visible. The diameter of the discharge piping must not however be lower than that of the outlet connection of the safety valve.
| ENGLISH Hydraulic system basic layout NOTA BENE: the drawing in the figure is an example.
| ENGLISH Instant domestic hot water production kit Warnings: if the instant hot water production kit is to be used, contact the company technical after-sales service. Stove positioning For correct product functioning, it is recommended to position it in a way that it is perfectly level, with the aid of a spirit level. REARM The figures below show the rearm positions of the tank (85°C) and H2O (100°C).
| ENGLISH SAFETY DEVICES Key: * = present, - = not present Circuit board: intervenes directly by sending the product into alarm conditions until complete cooling, in the case of: breakage of flue gas motor, pellet feed motor breakage, black out (if more than 10 seconds), no ignition STOVES Safety devices * * F 2.
| ENGLISH RADIATION AREA Area immediately near the hearth in which the heat caused by combustion is diffused, where no combustion materials must be present. REFLUX AREA Area where leaking of the combustion products is verified, from the appliance towards the installation room.
| ENGLISH Chimney or individual flue The chimney or individual flue must respond to the following requisites: seal the combustion products, be waterproof and adequately insulated in line with the use conditions; be realised with materials which resist the normal mechanical stress, heat, action of the combustion products and any condensate; have mainly vertical progress with deviations from the axis not higher than 45°; be adequately distanced from fuel or flammable materials through air space or
| ENGLISH <3m External pipe that is isolated 45° 45° Inspection Inspection Appliance connection to the flue and combustion products evacuation The flue must receive the discharge from only one heat generator. Direct discharge towards closed spaces is forbidden, even with clear sky. The direct discharge of the combustion products must be at roof and the smoke pipe must have the features provided in the "Chimney or individual flue" section.
| ENGLISH Connection to external air inlets The appliance must be able to use the necessary air to guarantee regular functioning through external air inlet. The air inlets must comply with the following requisites: have a total free section of at least 80 cm². must be protected by grates, metal net or suitable protections as long as they do not reduce the minimum section stated in the previous point and positioned in order to avoid them being obstructed.
| ENGLISH Control Board ON/OFF BUTTON Display of various Text messages TO ACCESS THE Menu OFF OPERATION POWER ADJUSTMENT TEMPERATURE SETTING Display icons key 16 Indicates the receipt of the radio signal On = during radio communication Off = no radio communication Flashing = excluded serial port Indicates the stove modulation On = the stove is working at the set power Flashing = the power at which the stove is working is different to the power set, the stove is modulating (for various reasons) In
| ENGLISH General menu 2 1 6 4 OFF 3 1 5 6 Go back - exit 2 3 Browse parameters: next (2); previous (3) 4 5 Modify setting data: increase (4); decrease (5) 6 Confirm - access Menu Set power 2 Set temperature 6 Set adjustments 6 Status 6 set h2o 2 2 enable chrono 2 2 STOVE STATUS 2 2 2 User menu 2 pellets summer/winter 2 HEAT.
| ENGLISH THE REMOTE CONTROL All that can normally be implemented through the LCD can be adjusted can be adjusted using the remote control.
| ENGLISH COMMISSIONING settings Once the power cable at the back of the stove has been connected, move the switch, also located on the back, to (I). The switch at the back of the stove powers the stove board. The stove remains off and a first screen appears on the panel reading OFF.
| ENGLISH Operation and logic OFF Ignition Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition phase. After ignition and having reached the control temperature, the stove interrupts the ignition phase and passes to STARTING. Starting During the starting phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and pass on to WORK.
| ENGLISH Additional thermostat N.B. : Installation must be performed by an authorised technician It is possible to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat following the procedure described in the next point (it is recommended to position the optional mechanical thermostat at a height of 1.50m from the ground).
| ENGLISH Menu structure 2 1 1 6 4 OFF 3 5 Go back - exit 2 3 Browse parameters: next (2); previous (3) 4 5 Modify setting data: increase (4); decrease (5) 6 Confirm - access Menu 6 2 Menu set power Power 01 - 05 set temperature set h2o 65 - 80°C Enable chrono on-off 2 set adjustments TEXT pellets 2 VALUE FUNCTION Selecting the power -30...
| ENGLISH Set power The following menu allows the power to be set. Minimum power 1, maximum power 5. Controls procedure Press key 6 and set power will appear Press key 6 to access and key 2 to proceed SET temperature will appear. Press 4 to increase the set and 5 to decrease it. Press key 6 to confirm and key 1 to return to the previous menus up to the initial status Set temperature The following menu allows the boiler temperature to be set The possible settings are: 65 - 80°C.
| ENGLISH No fuel: the stove can never develop a suitable flame, tending to remain very low even at high powers. at minimum power the stove tends to almost switch-off taking the stove into “no pellets” alarm condition. when the stove displays the “no pellets” alarm, there may be non-burned pellets inside the burn pot. Excess fuel: the stove develops a very high flame even at low power. the panoramic glass is very dirty, obscuring it almost totally.
| ENGLISH Programming example Let's suppose that the weekly programmer function is to be used and 4 time periods are to be used in the following way: 1st time period: from 08:00 to 12:00 every day of the week excluding Saturday and Sunday 2nd time period: from 15:00 to 22:00 only Saturday and Sunday with both times having a water temperature set of 75°C 1st time period switch-off Controls procedure: Press key 6 once and SET power will appear Set USER Press key 2 until USER SET Use keys 4 - 5 to enter th
| ENGLISH Adjusting language • see chapter: first ignition settings Display This menu allows to regulate the brightness of the display. The possible settings range from OFF - 10 to 31. Activating OFF, the back light of the display will go off after a preset delay. The back light will go on as soon as a key is pressed or if an alarm should be triggered in the machine. Controls procedure OFF Press key 6 and set power will appear. Press key 2 several times until user is displayed.
| ENGLISH Cleaning under user's responsibility Some images could be offset from the original model. DAILY Burn pot: remove the burn pot from the relevant compartment and free the holes using the appropriate fire irons supplied, remove the ash from the burn pot using a suction device. Suck the ash deposited in the brazier compartment. UPPER DIVIDER BURN POT KEEP THE CORRECT POSITION AS INDICATED IN THE FIGURE WEEKLY Cleaning the ash drawer: Empty the ash drawer every week or when required.
| ENGLISH Cleaning under user's responsibility Some images could be offset from the original model. MONTHLY Cleaning the deflector: The smoke deflector located under the cleaning springs of the heat exchanger must be removed every month. Move it as follows: remove part A of the door upper deflector fixed with 3 screws, remove part B of the door upper deflector fixed with 2 screws and remove the smoke central deflector as if it were a drawer.
| ENGLISH Routine maintenance Some images could be offset from the original model. B C D D C A B E C A Fumes motor (disassembly and cleaning and fumes pipe and "t"), new silicone in the provided points B Inspections of gaskets, ash drawer and door (replace them and apply silicone where envisioned) C Combustion chamber and heat exchanger (full cleaning) including ignition-plug pipe D Feed box (complete emptying and cleaning).
| ENGLISH Displays Display off START PELLET FEEDING Stove off The start phase is in progress The continuous feeding of the pellets during the ignition phase is in progress Ignition The ignition phase is in progress Start-up The start-up phase is in progress Burn pot cleaning The automatic burn pot cleaning is in progress Final cleaning Stand-by Cooling Work Modulation The final cleaning is in progress Start-up attempt while the stove is still in cooling mode Every time the stove displays one o
| ENGLISH ALARMS DISPLAY EXPLANATION SOLUTION Indicates the presence of an alarm. On: indicates the presence of an alarm Flashing: indicates the deactivation of the depression sensor. The alarm can be reset by pressing key 1 for 3 seconds only if the fumes motor has stopped and if 15 minutes have passed from when the alarm was displayed. Fumes motor fault Contact after-sales centre Fumes probe failure.
ENGLISH WARRANTY CONDITIONS EXTRAFLAME S.p.A., with offices in via dell’Artigianato 12 Montecchio Precalcino (VI), guarantees this product for 2 (two) YEARS from purchase date for manufacturer and material faults. The warranty becomes void in case the defect of conformity is not filed with the dealer within two months from date of its finding. The responsibility of EXTRAFLAME S.p.A.
ENGLISH All particulars subject to normal wear are not covered by warranty: This category includes: The gaskets, all ceramic or toughened glass, coverings and cast iron or Ironker grids, the painted, chrome or gold-plated details, the majolica, the handles and the electric cables. Colour variations, crackles and slight size differences f the majolica parts are not a reason for claims, as they are natural features of the materials themselves.
| ENGLISH 35
EXTRAFLAME S.p.A. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY +39.0445.865911 - +39.0445.865912 - info@extraflame.it - www.lanordica-extraflame.com Extraflame Extraflame si riserva reserves di variare the le right caratteristiche to vary the features e i dati riportate and datanel shown presente in this fascicolo bookletinatqualunque any momento time and ewithout senza preavviso, prior notice, al fine in order di migliorare to improve i propri its products. prodotti.